Whirlpool CHS-12RC User Manual

Page 3

Attention! The text in this document has been recognized automatically. To view the original document, you can use the "Original mode".

Advertising
background image

5.

Unlatch the two snap catches and swing the front panel

open on its hinges. If there is inadequate clearance to
swing the panel open, the front panel can also be lifted
off the hinges. The control panel cover may have to be
removed to lift the front panel off its hinges. Remove

the cover by removing the screws along the bottom
front edge. The cover then pulls straight off.

CAUTION:

Always

disconnect

electrical

power

to

the

machine when removing the control pane! cover.

The front panel then need only be cracked open to lift

it off the hinges. Temporarily replace the control panel

cover

as

power

must

be

provided

to

continue

the

cleaning operation.

With electrical power on and the service switch set to
the "normal on" position, proceed to:

A.

Shut off the water supply to the machine.

B.

Lift up gently on the thickness control arm until

the water has drained out of the reservoir pan and
all ice sheets are off the freezing plates.

C.

Release the thickness control and set the service

switch to the "clean" position.

Circulate for five minutes. Then set service switch to
"off" position to syphon out the water.

7.

Set service switch to "clean" position. Slowly pour the

cleaning solution into the water reservoir pan. If the
solution foams, stop pouring until the foam subsides
and then pour the rest of the solution.

8.

Allow the solution to circulate until the scale on the

freezing plate surface has dissolved.

9.

When the plates are clean, place the service switch in

the "off" position. This allows the cleaning solution to
syphon out of the reservoir pan into the drain.

NOTE: Severe scale formation on the freezing plates

may require repeating the cleaning process with a fresh
quantity

of

solution

if

after

20

to

30

minutes

of

circulating all the scale deposits are not removed.

If scale deposits remain on the side flanges a stainless

steel sponge or pad dipped in cleaning solution can be
used to scrub these surfaces. This can best be accom­
plished

after

the

removal

of

the

lower

water

distributors, (see steps 14 & 15)

10.

Turn on the water supply to the machine and set the

service

switch

to

"clean".

Allow

the

fresh

water

to

circulate for ten minutes.

11.

Place the service switch in the "off" position and allow

the

water

to

syphon

off

to

the

drain.

When

the

reservoir pan has refilled with water, place the service
switch in the "clean" position and allow the water to
circulate for ten more minutes.

12.

Place the service switch in the "off" position and allow

the water to syphon off to the drain.

6. Preheat the water system by pouring hot water into the

reservoir pan until the lower pump housing is covered.

13.

Remove the top water distributor tube. Remove the

two

wing

nuts

which

hold

the

distributor

tube

in

position on the top freezing plate. Pull out the water
pump

hose

from

the

right

end

of

the

distributor.

Pull out the rubber plug from the left end of the distri­
butor.

A

stiff

bristled

brush

of

approximately

the

same diameter as the distributor will facilitate removal
of scale accumulation.