Before yott start...

Proper installation is your responsibility.

A qualified technician should install
this range. Make sure you have
everything necessary for correct

installation. It is the responsibility of the
installer to comply with the installation
clearances specified on the

serial/rating plate. The serial/rating

plate is located on the oven frame
behind the door.

18" min

clearance

upper cabinet

to countertop

6" min. countertop space

from either side of range

cooktop to vertical wall or
other combustible material.

Important:

Observe all

governing codes

and ordinances.

Gas line can be

located through the

floor or through the
wall within this

shaded area.

Grounded electrical
outlet is required. See
Electrical requirements

Proper gas supply

connection must be
available. See Gas supply

requirements.

Check location where range will be
installed. The location should be
away from strong draft areas, such
as windows, doors, and strong
heating vents or fans. The range
should be located for convenient
use in the kitchen. Recessed
installations must provide complete
enclosure of the sides and rear of
range.

" NOTE: 30" min. when bottom of

wood or metal cabinet is
protected by not less than 1 /4"

flame retardant millboard

covered with not less than No. 28

MSG sheet steel, 0.015" stainless

steel, 0.024" aluminum or 0.020"
copper.

Gas supply line piping

MUST NOT interfere

with vent ductwork.

Width —29-15/16”

ALL OPENINGS IN THE WALL
OR FLOOR WHERE RANGE IS
TO BE INSTALLED MUST BE
SEALED.

WARNING: If the information

in this manual is not

followed exactly, a fire or
explosion may result
causing property damage,

personal injury or death.

— Do Not store or use gasoline

or other flammabie vapors
and liquids in the vicinity of

this or any other appliance.

— WHAT TO DO IF YOU SMELL

GAS

• Do Not try to light any

appliance.

• Do Not touch any electrical

switch; Do Not use any
phone in your building.

• Immediately call your gas

supplier from a neighbor's

phone. Follow the gas

supplier's instructions.

• If you cannot reach your

gas supplier, call the fire
department.

— Installation and service must

be performed by a qualified
installer, service agency or

the gas supplier.

A. WARNING

Fire Hazard

Do Not obstruct the flow of

combustion and ventilation air.

Personal Injury Hazard

Avoid installing cabinet storage
above the cooking surface. If
cabinets are already installed,
reduce the hazard of reaching over
a heated cooking surface by
installing a range hood. The range
hood should extend a minimum of 5
inches out from the bottom front of
the cabinets.
Reaching over a heated cooking

surface could result In a serious burn.

Electrical Shock Hazard

It is the customer’s responsibility:

• To contact a qualified electrical

installer.

• To assure that the electrical

installation is adequate and in
conformance with National
Electrical Code, ANSI/NFPA 70 —
latest edition*, and all local codes
and ordinances.

Failure to do so could result in fire,

electrical shock or other personal
injury.

Tools needed for
installation:

caulking gun
duct tape
metal snips
hand or electric drill

wood floors: 3/32" drill bit
concrete/ceramic lloor: 3/16” masonry drill bit

Copies of standards listed may be
obtained from:

* National Fire Protection Association

Batterymarch Park

Quincy, Massachusetts 02269

** American Gas Association

1515 Wilson Boulevard

Arlington, Virginia 22209

Panel A

36” min. clearance between the

top ot the cooking platform and
the bottom of an unprotected

wood or metal cabinet.

Island or peninsula installations
use 24" deep, flush back base
cabinets with no rear toe space.
If rear toe space is desired, use
27" or deeper base cabinet.

Cabinet opening dimensions
that are shown must be used.
Given dimensions are
minimum clearances and
provide required 0"
clearance.

NOTE: Clearances specified are for
combustible walls and materials that
have a density of 20 or more pounds
per cubic foot. No evaluation of

clearances has been made for
installations adjacent to materials
that are less than 20 pounds per cu.
ft. or to plastic tiles and sheeting.

The anti-tip bracket MUST
be instaiied. For detaiied

instructions, see Panei D.

Gas supply
requirements

Observe all governing codes and
ordinances.

A WARNING

Fire Hazard

• Range must be connected to a

regulated gas supply. This must be
checked by a qualified technician
before installing range.

• Do Not use an open flame to test

for leaks from gas connections.

• New, A.G.A. design-certified

flexible gas line should be used
when codes permit.

Failure to follow these instructions

could result in a fire, explosion or
personal injury.

This installation must conform

with local codes and ordinances. In
the absence of local codes,

installation must conform with

American National Standard, National

Fuel Gas Code ANSI Z223.1 — latest
edition**.

В

duct tape

Input ratings shown on

the seriai/rating piate are for
eievations up to 2,000 feet. For
elevations above 2,000 feet, ratings
are reduced at a rate of 4% for each

1,000 feet above sea level.