Carriage Bolt
1/4"-20x1/2"

Lens

Wing Nut
1/4"-20

Figure 5

MOUNTING AND WIRING THE SAFETY REVERSING
SENSORS

• Slide a 1/4"-20x1/2" carriage bolt head into the slot on

each sensor. Use wing nuts to fasten sensors to
brackets, with lenses pointing toward each other across
the door. Be sure the lens is not obstructed by a
bracket extension (Figure 5).

• Finger tighten the wing nuts.

Run the wires from both sensors to the opener. Use

insulated staples to secure wire to wall and ceiling.

• Strip 1/4" (6 mm) of insulation from each set of wires.

Separate white and white/black wires sufficiently to
connect to the opener terminal screws: white to 2 and
white/black to 3 (Figure 6).

ALIGNING THE SAFETY REVERSING SENSORS

Plug in the opener. The indicator lights in both the

sending and receiving eyes will glow steadily if wiring
connections and alignment are correct.

The sending eye amber indicator light will glow regardless
of alignment or obstruction. If the green indicator light in
the receiving eye is off, dim, or flickering (and the invisible
light beam path is not obstructed), alignment is required.

• Loosen the sending eye wing nut and readjust, aiming

directly at the receiving eye. Lock in place.

• Loosen the receiving eye wing nut and adjust sensor

until it receives the sender’s beam. When the green
indicator light glows steadily, tighten the wing nut.

TROUBLESHOOTING THE SAFETY
REVERSING SENSORS

1. If the sending eye indicator light does not glow steadily

after installation, check for:

• Electric power to the opener.

• A short in the white or white/black wires. These can

occur at staples, or at terminal connections.

• Incorrect wiring between sensors and opener.

• A broken wire.

2. If the sending eye indicator light glows steadily but the

receiving eye indicator light doesn't:

• Check alignment.

• Check for an open wire to the receiving eye.

3. If the receiving eye indicator light is dim, realign either

sensor.

NOTE: When the invisible beam path is obstructed or
misaligned while the door is closing, the door will
reverse. If the door is already open, it will not close. The
opener lights will blink 10 times. (If bulbs are not
installed, 10 clicks can be heard.) See page 21.

Invisible Light Beam
Protection Area

Safety Reversing Sensor

Safety Reversing Sensor

Connect Wire to
Opener Terminal Screws

Bell Wire

Finished Ceiling

OPENER TERMINAL SCREWS

Sensor
Connections

Door Control

Connections

(dotted line)

1

2

3

Bell Wire

Figure 6