Maximum ratings, Operating range, Capacitance[5 – Cypress CY7C028V User Manual

Page 6: Electrical characteristics, Capacitance

Advertising
background image

CY7C027V/027VN/027AV/028V

CY7C037V/037AV/038V

Document #: 38-06078 Rev. *B

Page 6 of 18

Maximum Ratings

Exceeding maximum ratings may shorten the useful life of the
device. User guidelines are not tested.

Storage Temperature ................................. –65

°

C to +150

°

C

Ambient Temperature with
Power Applied ............................................ –55

°

C to +125

°

C

Supply Voltage to Ground Potential................–0.5V to +4.6V

DC Voltage Applied to
Outputs in High-Z State ........................... –0.5V to V

CC

+0.5V

DC Input Voltage

[2]

.................................. –0.5V to V

CC

+0.5V

Output Current into Outputs (LOW)............................. 20 mA

Static Discharge Voltage.......................................... > 1100V

Latch-up Current.................................................... > 200 mA

Operating Range

Range

Ambient

Temperature

V

CC

Commercial

0

°

C to +70

°

C 3.3V

± 300 mV

Industrial

[3]

–40

°

C to +85

°

C 3.3V

± 300 mV

Electrical Characteristics

Over the Operating Range

Parameter

Description

CY7C027V/027VN/027AV/028V/CY7C037V/037AV/038V

Unit

-15

-20

-25

Min

Typ

Max

Min

Typ

Max

Min

Typ

Max

V

OH

Output HIGH Voltage
(V

CC

=Min., I

OH

= –4.0 mA)

2.4

2.4

2.4

V

V

OL

Output LOW Voltage (V

CC

=Min., I

OH

= +4.0 mA)

0.4

0.4

0.4

V

V

IH

Input HIGH Voltage

2.2

2.2

2.2

V

V

IL

Input LOW Voltage

0.8

0.8

0.8

V

I

IX

Input Leakage Current

−5

5

−5

5

−5

5

μA

I

OZ

Output Leakage Current

–10

10

–10

10

–10

10

μA

I

CC

Operating Current (V

CC

=Max. I

OUT

=0

mA) Outputs Disabled

Com’l.

125

185

120

175

115

165

mA

Ind.

[3]

140

195

mA

I

SB1

Standby Current (Both Ports TTL
Level) CE

L

& CE

R

≥ V

IH

, f=f

MAX

Com’l.

35

50

35

45

30

40

mA

Ind.

[3]

45

55

mA

I

SB2

Standby Current (One Port TTL Level)
CE

L

| CE

R

≥ V

IH

, f=f

MAX

Com’l.

80

120

75

110

65

95

mA

Ind.

[3]

85

120

mA

I

SB3

Standby Current (Both Ports CMOS
Level) CE

L

& CE

R

≥ V

CC

−0.2V, f=0

Com’l.

10

250

10

250

10

250

μA

Ind.

[3]

10

250

μA

I

SB4

Standby Current (One Port CMOS Lev-
el) CE

L

| CE

R

≥ V

IH

, f=f

MAX

[4]

Com’l.

75

105

70

95

60

80

mA

Ind.

[3]

80

105

mA

Capacitance

[5]

Parameter

Description

Test Conditions

Max

Unit

C

IN

Input Capacitance

T

A

= 25

°

C, f = 1 MHz,

V

CC

= 3.3V

10

pF

C

OUT

Output Capacitance

10

pF

Notes

2. Pulse width < 20 ns.
3. Industrial parts are available in CY7C028V and CY7C038V only.
4. f

MAX

= 1/t

RC

= All inputs cycling at f = 1/t

RC

(except output enable). f = 0 means no address or control lines change. This applies only to inputs at CMOS level standby I

SB3

.

5. Tested initially and after any design or process changes that may affect these parameters.