Campbell Hausfeld FP2091 User Manual

Page 5

Advertising
background image

Troubleshooting Chart

Symptom

Possible Cause(s)

Corrective Action

1. Switch in OFF position

2. No electrical power at wall outlet

3. Compressor has reached automatic

shut-off pressure

4. Motor overheated

5. Loose electrical connection

6. ON / OFF switch bad

7. Pressure switch bad

8. Defective motor

1. Lack of proper ventilation/room

temperature too high

2. Excessive air usage, compressor too

small

1. Open tank drain valve

2. Loose connections (fittings, tubing,

air hose, any connections, etc.)

3. Tank leaks

1. Excessive air usage, compressor too

small

2. Open tank drain valve

3. Loose connections (fittings, tubing,

air hose, any connections, etc.)

4. Pump wore out

1. Excessive water in tank

2. High humidity

1. Defective pressure switch

2. Defective safety valve

1. Make sure compressor is plugged in and switch is ON

2. Check circuit breaker or fuse at electrical panel.

3. Release air from tank until compressor restarts

automatically

4. Allow compressor to cool for approximately 30

minutes so thermal overload switch will reset. Make

sure compressor is run in a clean, well-ventilated area

where temperature will not exceed 100°F.

5. Check all electrical connections

6. Replace ON / OFF switch

7. Replace pressure switch

8. Replace pump / motor assembly

1. Move compressor to a clean,well ventilated area

where temperature will not exceed 100°F.

2. Decrease usage or purchase unit with higher air

delivery (SCFM)

1. Close tank drain valve

2. Check all connections with soap and water solution.

If a leak is detected, tighten. Or remove fitting and

apply pipe tape to threads and reassemble.

Do not disassemble check

valve. With air in tank, bleed tank first.

3. Check entire tank for leaks with soap and water

solution.

1. Decrease usage or purchase unit with higher air

delivery (SCFM)

2. Close tank drain valve

3. Check all connections with soap and water solution.

If a leak is detected, tighten. Or remove fitting and

apply pipe tape to threads and reassemble.

4. Replace pump / motor assembly

1. Drain tank, tilt tank to remove moisture

2. Move to area of less humidity; use air line filter

1. Replace pressure switch

2. Replace safety valve with genuine replacement part

Compressor will not run

Thermal overload

protector cuts out

repeatedly

Tank pressure drops

when compressor shuts

off

Compressor runs

continuously / air

output lower than

normal

Excessive moisture in

discharge air

Safety valve pops open

FP2090, FP2091, FP2094 Series

5