Cisco XM Universal Gateways Cisco AS5400XM User Manual

Page 65

Advertising
background image

A-11

Cisco AS5400XM Universal Gateway Chassis Installation Guide

OL-6418-02

Appendix A Replacing Memory Components

Replacing the Chassis Cover

Step 6

Reinstall all interface cables.

Step 7

Reconnect the two AC power cords to the power supply. Or, if using DC power, see

Figure A-9

, and

then complete Step

a

through Step

d

.

Warning

The illustration shows the DC power supply terminal block. Wire the DC power supply using the
appropriate lugs at the wiring end, or with no lugs, as illustrated. The proper wiring sequence is
ground to ground, positive to positive, and negative to negative. Note that the ground wire should
always be connected first and disconnected last.
Statement 197

Figure A-9

DC Power Supply Connections

Caution

Do not overtorque the terminal block contact screws. The recommended torque is 5.0 in.-lb (0.56 N-m).

a.

Insert the safety ground (green wires) into the terminal block ground connectors and tighten the
locking screws. Ensure that no bare wire is exposed.

b.

Insert the 48 VDC wires into the terminal block positive connectors (+) and tighten the locking
screws. Ensure that no bare wire is exposed.

c.

Insert the –48 VDC wires into the terminal block negative connectors (–) and tighten the locking
screws. Ensure that no bare wire is exposed.

d.

Make sure the power supply cords are secured to the cable strain-relief clamps on the DC power
supply with cable ties.

Warning

After wiring the DC power supply, remove the tape from the circuit breaker switch handle and
reinstate power by moving the handle of the circuit breaker to the ON position.
Statement 8

Step 8

Power up the universal gateway.

The internal power supply fan should power up.

On/off
switch

LEDs

31628

Terminal
block

Mounting screw

Mounting screw

Mounting

screw

IN OK

DC OK

OTF

IN OK

DC OK

OTF

LEDs

Terminal
block

Strain-relief

clamps

Strain-relief

clamps

Advertising