B electrical connections, New construction and four wire cord connection kit, Installation instructions – GE EER2000 User Manual

Page 6

Attention! The text in this document has been recognized automatically. To view the original document, you can use the "Original mode".

Advertising
background image

Installation Instructions

B Electrical Connections

cont.

B3

B4

B5

B6

B7

NEW CONSTRUCTION AND FOUR

WIRE CORD CONNECTION KIT

Complete 4 wire
cord kit. Beiow are
step by step
instructions on
how to install the
kit.

Remove the screws on

the terminal block with
a 1/4” nut driver or

Phillips screwdriver.

Knockout In center

of connection plate

may be taken out

Remove the ground
screw using a 5/16”
nut driver, then
remove and discard

the ground strap. Do

not discard the
ground screw, you

will need it later.

Install the four-wire

cord and strain

relief through the
hole in the

connection plate.

Ground

4 wire

B8

B9

BIO

B11

Attach the green lead

below the junction
block with the ground
screw that was
removed earlier.

Connect the red
and black leads to
the outside
terminals and the

white lead to the

center terminal.

Push the cord upward (to relieve strain),

while tightening the strain relief clamp.

Re-install the wire cover with the 5
screws removed earlier. Make sure the

wires do not become pinched between

the wire cover and mainback.

Wire

Cover

Three-wire connection continued on following page

Advertising