Rtc register, Stk17ta8 – Cypress AutoStore STK17TA8 User Manual

Page 17

Advertising
background image

STK17TA8

Document #: 001-52039 Rev. **

Page 17 of 23

RTC Register

* A binary value, not a BCD value.
0 - Not implemented, reserved for future use.
Default Settings of nonvolatile Calibration and Interrupt registers from factory
Calibration Register=00h
Interrupt Register=00h
The User should configure to desired value at startup or during operation and the value is then retained during a power failure.
[ ] designates values shipped from the factory. See

“Stopping And Starting The RTC Oscillator”

on page 14 .

Register

BCD Format Data

Function / Range

D7

D6

D5

D4

D3

D2

D1

D0

0x1FFFF

10s Years

Years

Years: 00-99

0x1FFFE

0

0

0

10s

Months

Months

Months: 01-12

0x1FFFD

0

0

10s Day of

Month

Day of Month

Day of Month: 01-31

0x1FFFC

0

0

0

0

0

Day of Week

Day of week: 01-07

0x1FFFB

0

0

10s Hours

Hours

Hours: 00-23

0x1FFFA

0

10s Minutes

Minutes

Minutes: 00-59

0x1FFF9

0

10s Seconds

Seconds

Seconds: 00-59

0x1FFF8

OSCEN

[0]

0

Cal

Sign

Calibration[00000]

Calibration values*

0x1FFF7

WDS

WDW

WDT

Watchdog*

0x1FFF6

WIE [0]

AIE [0]

PFE

[0]

0

H/L

[1]

P/L [0]

0

0

Interrupts*

0x1FFF5

M

0

10s Alarm Date

Alarm Day

Alarm, Day of Month: 01-31

0x1FFF4

M

0

10s Alarm Hours

Alarm Hours

Alarm, hours: 00-23

0x1FFF3

M

10 Alarm Minutes

Alarm Minutes

Alarm, minutes: 00-59

0x1FFF2

M

10 Alarm Seconds

Alarm Seconds

Alarm, seconds: 00-59

0x1FFF1

10s Centuries

Centuries

Centuries: 00-99

0x1FFF0

WDF

AF

PF

OSCF

0

CAL[0]

W[0]

R[0]

Flags*

[+] Feedback

Advertising