Electrical connections, New construction and branch circuit connection, Three-conductor branch circuit connection – GE PHP960DMBB User Manual

Page 7: Warning, Warning. d, Installation instructions, A warning

Attention! The text in this document has been recognized automatically. To view the original document, you can use the "Original mode".

Advertising
background image

Installation Instructions

ELECTRICAL CONNECTIONS

NEW CONSTRUCTION AND BRANCH

CIRCUIT CONNECTION

A WARNING:

Improper connection

of aluminum house wiring to copper leads

can result in an electrical hazard or fire. Use

only connectors designed forjoining copper

to aluminum and follow the manufacturer's

recommended procedure closely.

f

f

16"
Min.

____________ ^1

Li_

Installjunction box

so that it can be

reached through

the front of the

cabinet.

V

J

When making the wire

connections, use the
entire length of conduit

provided. The conduit
must not be shortened

(unless required by local
codes). The conduit length

is 4 ft. With the cooktop
in place, open the front of

the cabinet door. Insert
the wires from the conduit
through the opening of
thejunction box. The

conduit strain relief clamp must be securely
attached to thejunction box and the flexible
conduit must be securely attached to the clamp.

• When installing in new construction, or

• When installing in a mobile home, or

• When installing in a recreational vehicle, or

• When local codes do not permit grounding

through neutral:

a.

Insert conduit through strain relief and tighten.

b.

Attach the appliance grounding lead (green

or bare copper) in accordance with local
codes. If the residence grounding conductor is
aluminum, see

WARNING.

THREE-CONDUCTOR

BRANCH

CIRCUIT

CONNECTION

When

connecting

to

a

three-conductor

branch

circuit, if local codes permit:

a.

Connect the cooktop green ground conductor

lead to the branch circuit ground (green) using

a wire nut.

b.

Connect the cooktop red lead to the branch

circuit red lead in accordance with local

codes, using a wire nut.

c.

Connect the cooktop block lead to the

branch circuit block lead in accordance with

local codes, using a wire nut. If the residence

red, block or white leads ore aluminum

conductors, see

WARNING.

d.

Install Junction Box Cover.

Advertising
This manual is related to the following products: