INSTALLATION

INSTALLATION REQUIREMENTS

installation

hardware

Your air conditioner will install into standard double

hung windows with actual clear opening widths of

22 to 36 inches (558mm to 914mm) (FIG. 1).

Lower sash must open sufficiently to allow a clear

vertical opening of 14 inches (356mm). Side louvers

and the rear of the air conditioner must have clear
air space to allow enough airflow through the
condenser for heat removal. The rear of the unit

must be outdoors, not inside a building or garage.

ELECTRICAL SERVICE

Check your available electrical service. The power
supply available must be the same as that shown on

the unit nameplate (found on left side of cabinet).

All models are equipped with a 3-prong service plug to

provide proper service and safe positive grounding. Do
not change plug in any way. Do not use an adapter
plug. If your present wall outlet does not match your
plug, call a qualified electrician to make the necessary

corrections. SAVE CARTON and this OWNER'S

MANUAL for future reference. The carton is the best

way to store unit during winter or when not in use.

A CAUTION

To avoid risk of personal injury, property damage, or

product damage due to the weight of this device and

sharp edges that may be exposed:

• Air conditioners covered in this manual pose an

excessive weight hazard. Two or more people are

needed to move and install the unit.

To prevent injury or strain, use proper lifting and
carrying techniques when moving unit.

• Carefully inspect location where air conditioner will

be installed. Be sure it will support the weight of

the unit over an extended period of time.

• Handle air conditioner with care. Wear protective

gloves whenever lifting or carrying the unit. AVOID
the sharp metal fins of front and rear coils.

• Make sure air conditioner does not fall during

installation.

ITEM

NAME OF PARTS

Q'TY

A

SHORT SCREW

11

B

WOOD SCREW

5

C

L BRACKET

3

D

FOAM STRIP

1

E

FOAM SEAL

1

F

SIDE CURTAIN

2

G

DRAIN PIPE

1

H

SUPPORT BRACKET

1

REQUIRED TOOLS:

• Tight Fitting gloves

• 3/8-inch open end

• Standard screwdriver

wrench or adjustable
wrench

• Phillips screwdriver

• 1/4-inch hex socket

• Pliers

and ratcher

• Sharp knife

• Tape measure

• Electric drill

• 1/4-inch drill bit

Advertising