Product data sheets – Kenmore 2220698 User Manual

Page 22

Attention! The text in this document has been recognized automatically. To view the original document, you can use the "Original mode".

Advertising
background image

PRODUCT DATA SHEETS

Cyst Interior Water Filtration System Model WFI-NLCS200/NLCS200

Tested and certified by NSF International against ANSI/NSF Standard
42 for the reduction of Chlorine (Class I) Taste and Odor and against
ANSI/NSF Standard 53 for the reduction of Lead, Cysts and Turbidity.

Capacity; 200 gallons (757 liters),
Service fiow rate: 0.5 GPM (1.89 tVmin.) @ 60 psi.

Substance Reduction

U.S. EPA

Average

Maximum

Average

Minimum %

Average %

NSF Test

Aesthetic Effects

MCL

Influent

Effluent

Effluent

Reduction

Reduction

Number

Chlorine Taste/Odor

N/A

1.9 mg/L

N/A

0.06 mg/L

N/A

97%

994707

Particulate

N/A

108,667/mL*

N/A

45/mL

N/A

99.96%

994711

Contaminant

U.S. EPA

Average

Maximum

Average

Minimum %

Average %

NSF Test

Reduction

MCL

Influent

Effluent

Effluent

Reduction

Reduction

Number

Cyst

99.95%**

157,750/mL

55/mL

1.0/mL

99.9987%

99.9996%

994710

Turbidity

N/A

26 NTU

0.5 NTU

0.1 NTU

98.9%

99.5%

994710

Lead: @ pH 6.5

0.015 mg/L

0.160 mg/L***

0.011 mg/L

0.001 mg/L

93.5%

99.4%

994708

Lead: @ pH 8.5

0.015 mg/L

0.158 mg/L***

0.011 mg/L

0.001 mg/L

92.1%

99.3%

994709

It is essential that operational, maintenance, and filter
replacement requirements be carried out for this product to
perform as advertised.

Model NLCS200

Change the cartridge at least every 6-9

months. Use replacement cartridge NLCS200, part# 9002.
2001 suggested retail price of $39.95 U.S.A./$49.95 Canada.
Prices are subject to change without notice.

The product is for cold water use only.

Do not use with water that is microbiologically unsafe or of
unknown quality without adequate disinfection before or after

the system. Systems certified for cyst reduction may be used
on disinfected water that may contain filterable cysts.

Refer to the “Front cover” or “Assistance or Service” section

for the Manufacturer’s name, address and telephone number.

Refer to the “Warranty” section for the Manufacturer’s limited

warranty.

Application Guidelines/Water Supply Parameters

Water Supply

City or Well

Water Pressure

30- 120 psi (207 - 827 kPa)

Water Temperature

33°-100°F(0.6°-37.8° C)

‘Test requirement is at least 100,000 particles/ml of AC Fine Test Dust. “Cyst performance is % reduction based on NSF Standard 53. ***Test
requirement is 0.15 mg/L± 10%. These contaminants are not necessarily in your water supply. Performance may vary based on local water conditions.
® NSF is a registered trademark of NSF International.

22

Advertising