Warning, To replace belt – Kenmore 721.358205 User Manual

Page 14

Attention! The text in this document has been recognized automatically. To view the original document, you can use the "Original mode".

Advertising
background image

Remove string or hair that may be wrapped

around the agitator.

A

WARNING

B e careful w hen rem oving the

agitator as the belt tension is high.

F ailure to do so could result in

personal injury from the agitator

releasing quickly and snapping aw ay.

TO REPLACE BELT

Seat the left end of agitator into nozzle base.

Loop the new belt on the motor shaft.

Loop the other end of beit onto the belt

pulley on the right end of agitator.

Pull right end of agitator forward and seat it

into nozzie base.

To seat agitator right end, put right end of

agitator into slot in nozzle base as shown.

Press firmiy, checking to see that each end

is completely inserted.

To replace the nozzle cover, foilow the

NOZZLE COVER REMOVAL /

INSTALLATION section.

-14-