Kenmore 134966700 User Manual

Page 2

Attention! The text in this document has been recognized automatically. To view the original document, you can use the "Original mode".

Advertising
background image

PRE-INSTALLATION REQUIREMENTS

Tools

Required for Installation:

1. Phillips screwdriver

2. 10 mm socket with ratchet.
3. Channel-lock adjustable pliers.
4. Carpenter's level.

absence of local codes, with the National Electrical
Codes, ANSi/NFPA 70 (latest edition). If in doubt,
call a licensed electrician.

DO NOT

cut off or alter

the grounding prong on the power supply cord. In
situations where a two-slot receptacle is present,

it is the owner's responsibility to have a licensed

electrician replace it with a properly

grounded

three prong grounding type receptacle.

ELECTRICAL REQUIREMENTS

CIRCUIT

-

Individ ual, properly polarized and grounded

15 amp. branch circuit fused with 15 amp. time delay

fuse or circuit breaker.

POWER

SUPPLY

- 2 wire, with ground, 120 volt, single

phase, 60 Hz, Alternating Current.

NOTE:

Because of

potential inconsistent voltage capabilities, the use of this

washer with power created by gas powered generators,
solar powered generators, wind powered generators or
any other generator other than the local utility company

is not recommended.

OUTLET RECEPTACLE

-

Properly grounded 3-prong

receptacle to be located so the power supply cord is

accessible when the washer is in an installed position.

NOTE:

GFI (Ground Fault Interrupter) receptacle is not

required.

GROUNDING REQUIREMENTS

A WARNING

Improper connection of the equipment

grounding conductor can result in a risk of electrical
shock. Check with a licensed electrician if you are in
doubt as to whether the appliance is properly grounded.

1. The washer

MUST

be grounded. In the event of

malfunction or breakdown, grounding will reduce

the risk of electrical shock by a path of least

resistance for electrical current.

2. Since your washer is equipped with a power supply

cord having an equipment-grounding conductor
and a grounding plug, the plug

MUST

b e

plugged

into an appropriate, copper wired receptacle that
is properly installed and grounded in accordance

with all local codes and ordinances or in the

WATER SUPPLY REQUIREMENTS

Hot and cold water faucets

MUST

be installed within

42 inches (107 cm) of your washer's water inlet. The
faucets

MUST

be 3/4 inch (1.9 cm) garden hose type

so inlet hoses can be connected. Water pressure

MUST

be between 30 and 120 pounds per square inch (maximum
unbalance pressure, hot vs. cold, 10 psi.) Your water
department can advise you of your water pressure.

DRAIN REQUIREMENTS

1. Drain capable of eliminating 17 gals (64.3 L) per

minute.

2. A standpipe diameter of 1-1/4 in. (3.18 cm)

minimum.

3. The standpipe height above the floor should be:

Minimum height:

24 in. (61 cm)

Maximum height: 96 in. (244 cm)

NOTE:

Drain hose attached to the washer can reach a 79
in. (201 cm) high standpipe. For higher standpipe,
use hose P/N

134889610,

available from an

authorized parts distributor.