Grill lighting instruction, Lighting instructions ~17 – Kenmore 122.1613411 User Manual

Page 16

Attention! The text in this document has been recognized automatically. To view the original document, you can use the "Original mode".

Advertising
background image

Checking for LP gas leaks

Never test for leaks with a flame. Prior to first use, at

the beginning of each season, or every time your LP
gas tank is changed, you must check for gas leaks.

1. Make a 50/50 (soap/water) mild soap solution.

2. Turn the control knobs to full OFF position; then turn

gas ON at supply tank.

3. Apply the soap solution with a clean brush to all gas

connections. See below. If growing bubbles appear
in the solution the connections are not properly
sealed. Check each fitting and tighten or repair as
necessary.

Gas Connection Leak Check

4. If you have a gas connection leak you cannot repair,

turn gas OFF at supply tank, disconnect fuel line
from your grill and call 1-800-913-8999 or your gas
supplier for repair assistance.

5. Also apply soapy solution to the tank seams. See

below. If growing bubbles appear, shut tank OFF
and do not use or move it! Contact an LP gas
supplier or your fire department for assistance.

Gas Tank Leak Check

Grill Lighting Instruction

Grill Lighting Instructions for Main Burners

1. Do not smoke while lighting grill or checking gas

supply connections.

2. Be sure that LP gas tank is sufficiently full.

A

WARNING

Failure to open grill lid during the lighting
procedure could result in a fire or explosion

that could cause serious bodily injury, death,
or property damage.

3. Be sure all gas connections are securely

tightened.

4. Turn on gas supply.
5. Cpen the grill main lid.
6. Push and turn any main burner control knob to

H I p o s i t i o n . Push Electronic Ignition button for
3 to 5 seconds to light burner.

7. If the burner does not light after 5 seconds, turn

knob to CFF. Turn gas CFF at LP tank and wait
5 minutes for gas to clear. Then turn gas CN at

tank and repeat step 5

8. If burner still does not light, see Match Lighting

section and If Grill Still Fails to Light section on

following page.

9. To light additional burners, turn burner knob(s)

to HI ^ Push and hold electronic ignition button
to light burner. Adjust knob(s) to desired setting.

USING THE SIDE BURNER:

Inspect the gas supply hose prior to turning the gas

“ON”. If there is evidence of cuts, wear or abrasion,
it must be replaced prior to use. Do not use the
side burner if the odor of gas is present.

WARNING: Always keep your face and body as

far away from the burner as possible when
lighting.

LIGHTING INSTRUCTIONS FOR SIDE BURNER

1

.

2

.

3.

4.

Open side burner lid fully.
Push and turn side burner knob to HI position.
Push and hold Electronic Ignition button for 3-5
seconds to light burner.

If the side burner does not light after 5 seconds,

turn knob to OFF. Turn gas OFF at LP tank and
wait 5 minutes for gas to clear. Then turn gas
ON at tank and repeat step 2.

If burner still does not light, see Match Lighting

section and If Grill Still Fails to Light Section on

following page.

16