SECTION 5

SERVICE TECH. INFORMATION

A. TROUBLESHOOTING

AUTOMATIC ELECTRONIC DIAGNOSTICS
The faceplate timer (PWA) com­
puter has a self-diagnostic func­
tion for the electrical system, ex­
cept for input power and water
meter. The computer monitors electronic compo­
nents and circuits for correct operation. If a malfunc­
tion occurs, an error code appears in the faceplate
display.

The chart below shows the error codes that could
appear, and the possible defects for each code.

While an error code appears in the display, all face
plate buttons are inoperable except the SELECT but­
ton. SELECT remains operational so the service per­
son can make the MANUAL INITIATED ELEC­
TRONIC DIAGNOSTICS (below) to further isolate
the defect, and check the water meter.

CODE

POSSIBLE DEFECT

MOST LIKELY

LESS LIKELY

Erri, ЕггЗ,
Err4

motor inoperative / wiring harness or connection to switch / position switch / valve defect causing
high torque_________________________________________________________________________

Errs

faceplate timer (PWA)

PROCEDURE FOR REMOVING ERROR CODE FROM FACEPLATE:

1. Unplug transformer from outlet 2. Correct

defect 3. Plug in transformer 4. Wait for 8 minutes. The error code will return if the defect was not corrected.

MANUAL INITIATED ELECTRONICS
DIAGNOSTICS

To enter diagnostics, press the SELECT button
and hold for three seconds.

You will see the following display, showing valve
cycle position, position switch status (open or
closed), and turbine operation.

valve position indicator

turbine count {water
flowing)

sOFF

1

II II

1

LI ULL

Л

SOFF

4

\

no

\

______X

3

gggg; _ ;

WATFR FLOW

___ WATER FLOW___

position switch

indicator (open)

turbine count (no
water flowing)

TURBINE OPERATION: If no water is flowing

through the softener, the turbine indicator displays
three zeros. When water is flowing, the flow bar
scrolls across the display, and a 000 to 199 count re­
peats for each gallon of water passing through the
turbine. To check for positive operation of the tur­
bine if zeros are shown, open a nearby soft water
faucet and observe the turbine count and flow bar.

If you don't get a reading in the display, with faucet
open, pull the sensor from the valve outlet port.

Pass a small magnet back and forth in front of the
sensor. You should get a reading in the display. If
you get a reading, unhook the in and out plumbing
and check the turbine for binding.

POSITION

SWITCH

SENSOR

HOUSING

TURBINE

TURBINE

SUPPORT AND

SHAFT

VALVE

OUTLET

POSITION SWITCH STATUS: With the valve in ser­
vice, or any of the recharge cycles, the switch indica­
tor will show open -*K-. While the valve is rotating
from one position to another, the indicator will
show the switch closed A defect is probable if
indications vary from this pattern.