Thank You for purchasing a Kenmore water heater. Properly
installed and maintained, it should give you years of trouble

free service, if you should decide that you want the new water

heater professionally installed by Sears call 1-800-4-MY-HOME®.
They will arrange for prompt, quality installation by Sears
authorized contractors.

Abbreviations Found In This Instruction Manual:

CSA - Canadian Standards Association

ANSI - American National Standards Institute

NFPA - National Fire Protection Association

ASME - American Society of Mechanical Engineers

GAMA ” Gas Appliance Manufacturers Association

This gas-fired water heater is design certified by CSA

INTERNATIONAL under American National Standard/CSA

Standard for Gas Water Heaters ANSI Z21.10.1 • CSA 4.1

(current edition).

Read the “Safety Precautions" section, page 3 of this manual

first and then the entire manual carefully, if you don't follow
the safety rules, the water heater will not operate properly, it
could cause DEATH. SERIOUS BODILY INJURY AND/OR

PROPERTY DAMAGE.

This manual contains instructions for the installation,
operation, and maintenance of the gas-fired water heater. It
also contains warnings through out the manual that you must

read and be aware of. Ail warnings and all instructions are

essential to the proper operation of the water heater and
your safety. Since we cannot put everything on the first few

pages, READ THE ENTIRE MANUAL BEFORE ATTEMPTING

TO INSTALL OR OPERATE THE WATER HEATER.

The installation must conform with these instructions and
the local code authority having jurisdiction. In the absence of
local codes, installations shall comply with the following:

In the United States: The National Fuel Gas Code ANSI
Z223.1/NFPA 54. This publication is available from the
Canadian Standards Association, 8501 East Pleasant Valley
Rd, Cleveland Ohio 44131, or The National Fire Protection
Association, 1 Batterymarch Park, Quincy, MA 02269.

If after reading this manual you have any questions or do not
understand any portion of the instructions, call the Sears
Service Center.

Carefully plan the place where you are going to put the water
heater. Correct combustion, vent action, and vent pipe
installation are very important in preventing death from
possible carbon monoxide poisoning and fires. See
Figure 1.

Examine the location to ensure the water heater complies
with the Facts to Consider About the Location section in this
manuai.

For California installation this water heater must be braced,
anchored, or strapped to avoid falling or moving during an
earthquake. See instructions for correct installation
procedures. Instructions may be obtained from your local
dealer, wholesaler, public utilities or Caiifornia Office of the
State Architect, 400 P Street, Sacramento, CA 95814.

Massachusetts Code requires this water heater to be
installed in accordance with Massachusetts 248-CMR 2.00:
State Plumbing Code and 248-CMR 5.00.

Complies with SCAQMD rule #1121 and districts having
equivalent NOx requirements.

PRODUCT

SPECIFICATIONS

MODEL NUM^R

TANK

CAPACITY

IN GALS (LTRS)

■nT>E

OF

GAS

BTU

RATE

RECOVERY

RATE GALS.

PBTHOUR

@90TRISE

MINIMUM

VENT PIPE

INOTES

(mm)

DIAMETER

INCHES

(mm)

DIMENSIONS

IN INCHES (mm)

HEIGHTTO

JACKETTOP

153.333315 HA

30(114)

NATURAL

32,000

32.8

3" (76)

15 3/4" (400)

55 1/4" (1,403)

153.333345

30(114)

NATURAL

32,000

32.8

3" (76)

15 3/4" (400)

55 1/4" (1,403)

153.333415 HA

40(151)

NATURAL

32,000

32.8

3"(76)

181/4" (464)

53 1/4" (1,353)

153.333445

40(151)

NATURAL

32,000

32.8

3”(76)

181/4" (464)

53 1/4" (1,353)

153.333545

50(189)

NATURAL

32,000

32.8

3”(76)

201/4" (514)

55 1/2" (1,410)