PRODUCT DATA SHEETS

Base Grille Water Filtration System

Model WF-NLC240V/NLC240V Capacity 240 Gallons (908 Liters)

Tested and certified by NSF International against ANSI/NSF Standard
42 for the reduction of Chlorine, Taste and Odor, Particulate Class T;
and against ANSI/NSF Standard 53 for the reduction of Lead,
Mercury, Atrazine, Benzene, Toxaphene, p-dichlorobenzene, 2, 4-D,
Cysts, Turbidity and Asbestos.

This system has been tested according to ANSI/NSF 42/53 for the reduction of the substances iisted below. The concentration of
the indicated substances in water entering the system was reduced to a concentration less than or equal to the permissible limit for
water leaving the system, as specified in ANSI/NSF 42/53.

Substance Reduction
Aesthetic Effects

NSF Reduction
Requirements

Average
Influent

Influent Challenge
Concentration

Maximum
Effluent

Average
Effluent

Minimum %
Reduction

Average %
Reduction

NSF Test
Number

Chlorine Taste/Odor

Particulate Class 1*

>50%
>85%

2.0 mg/L
5,366,667/
mL

2.0 mg/L± 10%
At least 10,000
partides/ml

0.06 mg/L
4,100/mL"

0.05 mg/L
2,300/mL

97.1%
99.3%

97.5%
99.9%

507173-02
507175-02

Contaminant

Reduction

NSF Reduction
Requirements

Average
Influent

Influent Challenge
Concentration

Maximum
Effluent

Average
Effluent

Minimum %
Reduction

Average %
Reduction

NSF Test
Number

Lead: @ pH 6.5
Lead; @ pH 8.5

0.01 mg/L
0.01 mg/L

0.16 mg/L"*
0.15 mg/L*"

0.15 mg/L ± 10%
0.15 mg/L ± 10%

0.001 mg/L
0.001 mg/L

0.001 mg/L
0.001 mg/L

99.35%
99.31%

99.35%
99.31%

507601- 01
507602- 01

Mercury: @ pH 6.5
Mercury: @ pH 8.5

0.002 mg/L
0.002 mg/L

0.0061 mg/L
0.0057 mg/L

0.006 mg/L ± 10%
0.006 mg/L ± 10%

0.0004 mg/L
0.0008 mg/L

0.0002 mg/L
0.00051 mg/L

93.5%
85.8%

96.7%
91.2%

507603- 02
507604- 02

Benzene

0.005 mg/L

0.0138 mg/L

0.015 ± 10%

0.0005 mg/L

0.0005 mg/L

96.3%

96.3%

507183-02

p-dichlorobenzene

0.075 mg/L

0.220 mg/L

0.225 ±10%

0.0005 mg/L

0.0005 mg/L

99.7%

99.7%

507186-02

Toxaphene

0.003 mg/L

0.014 mg/L

0.015 ±10%

0.0014 mg/L

0.001 mg/L

90.0%

92.9%

507185-02

Atrazine

0.003 mg/L

0.009 mg/L

0.009 mg/L ± 10%

0.0013 mg/L

0.00036 mg/L

85.6%

95.9%

507181-02

2, 4-D

0.07 mg/L

0.197 mg/L

0.215 ±10%

0.058 mg/L

0.0137 mg/L

70.6%

93.06%

507180-02

Asbestos

99%

26x 10'

10'to 10*fibers/L***‘

0.18x10'mg/L

0.18x10'mg/L

99.93%

99.93%

507178-02

Cysts""*
Turbidity

99.95%
0.5 NTU

111,000/mL
11.08 NTU

50.000/L min.

11± 1 NTU

1 mg/L

0.13 NTU

1 mg/L

0.078 NTU

99.99%
98.8%

99.99%
99.3%

507187-02
507751-02

Test Parameters: pH = 7.5 ± 0.5 unless otherwise noted. Flow = 0.5 gpm (1.9 Lpm). Pressure = 60 psig (413.7 kPa). Temp. =
(17.2'’C).

■ It is essential that operational, maintenance, and filter

replacement requirements be carried out for the product to

perform as advertised.

■ Model WF-NLC240V Change cartridge at least every 6-9

months. Use replacement cartridge NLC240V, part #9908.
2003 suggested retail price of $39.95 U.S.A./$49.95 Canada.

Prices are subject to change without notice.

■ The product is for cold water use only.

■ Do not use with water that is microbiologically unsafe or of

unknown quality without adequate disinfection before or after

the system. Systems certified for cyst reduction may be used
on disinfected waters that may contain filterable cysts.

■ Refer to the front cover or “Accessories" section for the

Manufacturer’s name, address and telephone number.

■ Refer to the “Warranty” section for the Manufacturer’s limited

warranty.

Application Guidelines/Water Supply Parameters

Water Supply

City or Well

Water Pressure

30- 120 psi (207 - 827 kPa)

Water Temperature

OS'* -100°F (C.G" - 37.8'* C)

Service Flow Rate

0.5 gpm (1.9 tymin.) @ 60 psi.

‘Class I particle size: >0.5 to <1 urn

“Test requirement is at least 100,000 particles/mL of AC Fine Test Dust.

‘“These contaminants are not necessarily in your water supply. Performance may vary based on local water conditions.

““Fibers greater than 10 um in length
““Based on the use of Cryptosporidium parvum oocysts