If plenum is wider than stiffener:

2. The five reference hole marks you’ve made on

the plenum outline the area that must be cut out.

Mark straight lines connecting the five points.

WARNING: Wear safety glasses! Be sure not to drill
or cut into air conditioner coil or tubing! If electric drill

is used, be sure it is properly grounded.

3. Drill or punch a large hole In one corner of the

area to be cut out. This will allow you to insert tin
snips or a metal saw.

4. Cut along the lines connecting the five points. If

any of the cut edges are rough, file them smooth.

5. Drill the remaining holes marked on the plenum

with a 1/8" drill bit.

6. Mount the stiffener with the mounting tabs facing

out toward you. Use the seven sheet metal
screws, supplied, to fasten the stiffener. Make
sure the stiffener is flush with the plenum and is
airtight. Seal around the edge with caulking (not
furnished) if necessary.

7. Using the two finger grips (Fig. 9) on the lower

edge of the front panel, simply lift the front panel
about 1/8" straight up, swing the lower edge out,
pull down until the front panel is free. Remove
lower rod screw (Fig. 9).

Disconnect media motor wiring at the electrical

disconnect. Grasp both ends of the electrical
disconnect and simply pull apart (Fig. 9).

WARNING: Do not pull on wires to separate
electrical connector.

Upper Case Electrical Disconnect

Remove the reservoir assembly. Remove the
lower case from the humidifier by unfastening

the latches on both sides and removing the

lower rod screw. Set the lower case, reservoir
media wheel assembly, and front panel aside.
Remove the humidistat from the lower case.

8. Hang the upper case assembly on plenum stiff­

ener mounting tabs (Fig. 7). Tabs may have to

be bent out slightly to fit into the slots in the
back of the upper case assembly. Secure the
upper case to the stiffener by pressing the

capped fastener (No. 47, Page 16) through the

back of the humidifier and into hole “A” (Fig. 10).

NOTE: It is very important that this fastener be
used. If the upper case is not attached with the

fastener, it could be dropped and damaged during

routine maintenance.

HUMIDISTAT

1 ,

Locate the humidistat on the return (cold) air
plenum (Fig. 11). DO NOT install the humidistat

on the supply (hot) air plenum because the

humidistat cannot accurately measure indoor
relative humidity and will cause the humidifier to

function improperly.

Return

Air

Plenum

Gasket

Fig. 11

2. The humidistat mounts in a horizontal position.

Using gasket as a template, mark the location

of the two mounting holes and the opening for
the humidistat on the return air plenum.

3. Drill 1/8" holes for two mounting screws.

Cut out the opening for the humidistat.