D. checklist ... to help you save money, Care of your water softener – Kenmore ULTRASOFT 625.38818 User Manual

Page 17

Attention! The text in this document has been recognized automatically. To view the original document, you can use the "Original mode".

Advertising
background image

SECTION 3

CARE OF YOUR WATER SOFTENER

D. CHECKLIST ... TO HELP YOU SAVE MONEY

If your water softener fails to work, make the following easy checks. Often, you will find what's wrong your­
self and you won't have to call and wait for service. If you do not find anything wrong, while making the
checks, and your softener still does not work, call the Kenmore Water Line at 1-800-426-9345.

Note:

1. Also read ERROR CODE, page 2-1.

2. If an error code is not displayed, press and hold the SELECT button until the display changes. Then, press
the SELECT button again and hold until a flashing code appears. It must show SR25 for UltraSoft 175 or SR26
for UltraSoft 180. If any other number shows, the face plate computer is working on incorrect input and would
probably be the cause of the problem. To set SR25 or SR26, press either the UF[7^ or DOWNlvl button. When
the correct model code shows, press SELECT to return a flashing 12:00 AM display. Reset the present time, hard­
ness number, etc., pages 1-3 and 1-4.

PROBLEM

CAUSE

CORRECTION

N o so ft w a ter

No salt (or salt bridged) in the storage tank

Add salt, or break the salt bridge (page 3-1). Press

RECHARGE button and hold for 3 seconds to start
a regeneration (see page 2-1).

Transformer unpiugged at the wall outlet, or

power cabie leads loose from the electronic
board, fuse blown, circuit breaker popped, or

circuit switched off.

Check for loss of power due to any of these and
correct. With the power back on, look at the time
display and read PROGRAM MEMORY, page 2-1.

Manuai bypass valve(s) in bypass position

Look at FIG.14 on page 4-1. Move the stem in a

single valve to service. In a 3-valve bypass, open
the inlet and outlet valves, and be sure to fully close
the bypass valve.

Dirty, plugged or damaged nozzle & venturi

Take apart and clean or replace damaged parts (see
page 3-2).

Valve drain hose plugged or restricted

The drain hose must not have kinks, sharp bends,
or be raised too high above the softener (see page

16 in your

installation manual).

W a ter h a rd so m etim es

Hardness number setting too low

Press and release the SELECT button until
HARDNESS shows In the display. Read the
hardness number in the display and be sure the

same grains per gallon number is shown on your
water analysis report. See page 1 -4 to reset. Press
and release the SELECT button until the present
time shows in the display.

Incorrect SR code selected

Press and hold the SELECT button until the display
changes. Then, press the SELECT button again
and hold until a flashing code appears. Use the UP
or DOWN buttons to select the correct code for your

softener.

Using hot water when softener is regenerating Avoid using hot water during this time because the

water heater refills with hard water (see Automatic

Bypass, page 2-4).

Increase in the grains of hardness in your water

supply

Ask your Sears retail store for a new water analysis.
Then make a new hardness number setting (page

1-4).

B rin e ta n k flo o d ed

Restricted drain line

Checkforkinks, bends or obstructions (see page 16
in your

Installation manual).

Plugged or dirty nozzle & venturi

Take apart and clean or replace damaged parts (see
page 3-2).

Valve-rotor disc & seals

Check for scratches or grooves, replace if needed.

3 - 4

Problems, Questions? Call 1-800-426-9345 Kenmore Water Line

Advertising