VENTING INSTRUCTIONS

Ref

Description

US Installations

A

Clearance above grade, veranda, porch, deck, or balcony

12 inches (30 cm)

B

Clearance to window or door that may be opened

12 inches (30 cm)

C

Clearance to permanently closed window

*

D

Vertical clearance to yentilated soffit, located aboye the terminal within a
horizontal distance of 2 feet (61 cm) from the center line of the terminal

*

E

Clearance to unyentilated soffit

*

F

Clearance to outside corner

*

G

Clearance to inside corner

*

H

Clearance to each side of center line extended aboye meter/regulator
assembly

*

I

Clearance to seryice regulator yent outlet

*

J

Clearance to nonmechanical air supply inlet to building or the combustion air
inlet to any other appliance

12 inches (30 cm)

K

Clearance to a mechanical air supply inlet

3 feet (91 cm) above if within

10 feet (3 m) horizontally

L

Clearance aboye payed sidewalk or payed driveway located on public property ®

*

M

Clearance under veranda, porch, deck, or balcony @

*

© A vent shall not terminate directly above a sidewalk or paved driveway that is located between two single family dwellings and serves

both dwellings.

© Permitted only if veranda, porch, deck, or balcony is fully open on a minimum of two sides beneath the floor.

* For clearances not specified in ANSI Z223.1/NFPA 54 or CSA B149.1, clearances are in accordance with local installation codes and the

requirements of the gas supplier.