Pressure test - check for leaks – Kenmore 7146611 User Manual

Page 16

Attention! The text in this document has been recognized automatically. To view the original document, you can use the "Original mode".

Advertising
background image

SECTION 4

STEP BY STEP GUIDES TO INSTALL

:

4E.

PRESSURE TEST - CHECK FOR LEAKS

TESTING YOUR PLUMBING WORK FOR WATER

LEAKS.

FIG. 12

MAIN WATER SHUTOFF VALVES

CAUTION:

TO AVOID WATER OR AIR PRESSURE DAMAGE TO FIL­
TER INNER PARTS, AT TO FLUSH PIPE CHIPS OR OTH­

ER RESIDUE FROM THE WATER PIPES, BE SURE TO
DO THE FOLLOWING STEPS EXACTLY AS
INSTRUCTED.

Look at the picture in Figure 13 showing your kind of by­
pass valve (s).

1. Fully open two cold, filtered water faucets nearby the

filter.

2.

Place bypass valve(s) in “bypass” position. On a

single valve, slide the stem into BYPASS. On a three valve
system, close the inlet and outlet valves and open the by­

pass valve.

3.

Fully open the house main water pipe shut off valve.

Observe steady water flow from both open faucets.

4.

Place bypass valve(s) in “Service”, EXACTLY as fol­

lows. KEEP FILTERED WATER FAUCETS OPEN.

a.

SINGLE BYPASS VALVE:

SLOWLY

slide the valve

stem towards “Service”, pausing several times to allow
the filter to pressurize slowly.

b.

THREE VALVE BYPASS: Fully close the bypass valve

and open the outlet valve.

SLOWLY

open the inlet valve,

pausing several times to allow the filter to pressurize

slowly.

5.

AFTER ABOUT THREE MINUTES, OPEN A HOT

WATER FAUCET FOR ABOUT ONE MINUTE, OR UN­
TIL ALL AIR IS EXPELLED, THEN CLOSE.

6. CLOSE BOTH COLD WATER FAUCETS.

7.

Check your plumbing work for leaks and fix right away

if any are found. BE SURE TO OBSERVE PREVIOUS
CAUTION NOTES.

FIG. 13

BYPASS VALVE (S)

FILTERED WATER

SERVICeHARD

WATER

BYPASS

SINGLE-PLASTIC

PULL STEM

OUTWARD

FOR

SERVICE

Push

Inward

For

Bypass

3-VALVE

SERVICE

Close Bypass Valve

Open Inlet & Outlet Valves

BYPASS

Open Bypass Valve

Close Inlet & Outlet Valves

16