Water piping, Warning, Caution – Kenmore POWER MISER 153.33926 User Manual

Page 12: Adanger

Attention! The text in this document has been recognized automatically. To view the original document, you can use the "Original mode".

Advertising
background image

* Special Conditions Created by Mechanical Exhausting or

Fireplaces: operation of exhaust fans, ventilation systems,
clothes dryers or fireplaces may create conditions requiring
special attention to avoid unsatisfactory operation of installed
gas utilization equipment.

Water Piping

ADANGER

Water

temperature

over

125T

(52°C) can cause severe burns
instantly resulting in severe injury
or death.

Children,

elderly,

and

the

physically

or

mentally

disabled

are at highest riskfor scald injury.

Feel

water

before

bathing

or

showering.

Temperature limiting valves are

available.

Read instruction manual for safe

temperature setting

HOTTER WATER CAN SCALD:

Water heaters are intended to produce hot water. Water heated
to a temperature which will satisfy space heating, clothes
washing, dish washing, cleaning and other sanitizing needs
can scald and permanently injure you upon contact. Some
people are more likely to be permanently injured by hot water
than others. These include the elderly, children, the infirm, or
physically/mentally handicapped. If anyone using hot water in
your home fits into one of these groups or if there is a local
code or state law requiring a certain temperature water at the
hot water tap, then you must take special precautions. In
addition to using the lowest possible temperature setting that
satisfies your hot water needs, a means such as a ‘mixing
valve, shall be used at the hot water taps used by these people
or at the water heater. Mixing valves are available at plumbing
supply or hardware stores. See Figure 14. Valves for reducing
point of use temperature by mixing cold and hot water are also
available. Follow manufacturer’s instructions for installation
of the valves. Before changing the factory setting on the
thermostat, read the

Temperature Regulation

section in this

manual.

FÎGUFŒ14.

A

WARNING

Toxic Chemical Hazard

Do not connect to non-potable water system.

This water heater shall not be connected to any heating systems
or component(s) used with a non-potable water heating
appliance.

Toxic chemicals, such as those used for boiler treatment shall
not be introduced into this system.

Water supply systems may, because of such events as high
line pressure, frequent cut-offs or the effects of water hammer
have installed devices such as pressure reducing valves, check
valves, back flow preventers, etc. to control these types of
problems. When these devices are not equipped with an
internal by-pass, and no other measures are taken, the devices
cause the water system to be closed. As water is heated, it
expands (thermal expansion) and closed systems do not allow

for the expansion of heated water.

The water within the water heater tank expands as it is heated
and increases the pressure of the water system. If the relieving
point of the water heater’s temperature-pressure relief valve is
reached, the valve will relieve the excess pressure. The
temperature-pressure relief valve is not intended for the
constant relief of themial expansion. This is an unacceptable
condition and must be corrected, it is recommended that any
devices installed which could create a closed system have a
by-pass and/or the system have an expansion tank to relieve

the pressure built by thermal expansion in the water system.

Refer to the

Thermal Expansion

section under

Troubleshooting

Guide

or contact local plumbing authority or local Sears Service

Center on how to control this situation.

NOTE: To protect against untimely corrosion of hot and cold
water fittings, it is strongly recommended that di-eiectric
unions or couplings be installed on this water heater when
connected to copper pipe.

CAUTION

Property Damage Hazard

Avoid water heater damage.

Install thermal expansion tank if necessary.

Do not apply heat to cold water inlet.

’ Contact qualified installer or Sears Service Center.

Figure 15 shows the typical attachment of the water piping to

the water heater. The water heater is equipped with 3/4” NPT
water connections.

NOTE: if using copper tubing, solder tubing to an adapter
before attaching the adapter to the cold water inlet
connection. Do not solder the cold water supply line directly
to the cold water inlet it will harm the dip tube and damage
the tank.

• Look at the top cover of the water heater. The water outlet is

marked "HOT”. Put two or three turns of teflon tape around

the threaded end of the threaded-to-sweat coupling and
around both ends of the 3/4” NPT threaded nipple. Using
flexible connectors, connect the hot water pipe to the hot
water outlet on the water heater.

12

Advertising