Grill lighting instruction, Using the side burner, Warning – Kenmore 122.166489 User Manual

Page 11

Attention! The text in this document has been recognized automatically. To view the original document, you can use the "Original mode".

Advertising
background image

Checking for LP gas leaks

Never test for leaks with a flame. Prior to first use, at

the beginning of each season, or every time your LP
gas tank is changed, you must check for gas leaks.

1. Make a 50/50 (soap/water) mild soap solution.

2. Turn the control knobs to full OFF position; then turn

gas ON at supply tank.

3. Apply the soap solution with a clean brush to all gas

connections. See below. If growing bubbles appear

in the solution the connections are not properly

sealed. Check each fitting and tighten or repair as

necessary.

Gas Connection Leak Check

4. If you have a gas connection leak you cannot repair,

turn gas OFF at supply tank, disconnect fuel line
from your grill and call 1-800-4-MY-HOME or your
gas supplier for repair assistance.

5. Also apply soapy solution to the tank seams. See

below. If growing bubbles appear, shut tank OFF

and do not use or move it! Contact an LP gas
supplier or your fire department for assistance.

Gas Tank Leak Check

Grill Lighting Instruction

Grill Lighting Instructions for Burner

1. Do not smoke while lighting grill or checking

gas supply connections.

2. Be sure that LP gas tank is sufficiently full.

3. Be sure all gas connections are securely

tightened.

4. Open the grill main lid and side burner lid.

5. Push and turn any main burner knob to ^Hl

position, hold in for 3 to 5 seconds until burner

ignites.

6. To light additional burners, push and turn burner

knob(s) to^ HI or ON and hold in for 3 to 5

seconds until burner(s) ignites, then adjust

knob(s) to desired setting.

7. If the burner does not light after 5 seconds, turn

knob to OFF. Turn gas OFF at LP tank and wait 5
minutes for gas to clear. Then turn gas ON at

tank and repeat step 5.

8. If burner still does not light, see Match Lighting

section and If Grill Still Fails to Light section on

following page.

LIGHTING INSTRUCTIONS FOR ROTISSERIE BURNER

1. Open lid during lighting.

2. To ignite, turn rôtisserie knob to j(iON, hold for 3 to

5 seconds until burner ignites. If ignition does not

occur in 5 seconds, turn knob to OFF, wait 5

minutes and repeat the lighting procedure.

3. Important: When using the Rôtisserie Burner, do not

use the Main Burners.

4. If burner still does not light, see Match Lighting

section and If Grill Still Fails to Light Section on

following page.

USING THE SIDE BURNER:

Inspect the gas supply hose prior to turning the gas

“ON”. If there is evidence of cuts, wear or abrasion,

it must be replaced prior to use. Do not use the

side burner if the odor of gas is present.

WARNING: Always keep your face and body as

far away from the burner as possible when

lighting.

LIGHTING INSTRUCTIONS FOR SIDE BURNER

• Open side burner lid fully.
• Push and turn side burner knob to^ON position,

hold in for 3 to 5 seconds until burner ignites.

• If the side burner does not light after 5 seconds,

turn knob to OFF, turn gas OFF at LP tank and

wait 5 minutes for gas to clear. Then turn gas ON

at tank and repeat step 2.

• 4. If burner still does not light, see Match Lighting

section and If Grill Still Fails to Light section on

A

WARNING

Failure to open grill lid during the lighting

following page.

procedure could result in a fire or explosion

that could cause serious bodily injury, death,

or property damage.

1 0

Advertising