Use a heavy metal vent. Do not use plastic or metal foil vent.

Rigid metal vent is recommended to prevent crushing and
kinking.

Flexible metal vent must be fully extended and supported when

the dryer is in its final position. Remove excess flexible metal vent
to avoid sagging and kinking that may result in reduced airflow
and poor performance.

An exhaust hood should cap the vent to prevent rodents and

insects from entering the home.

Exhaust hood must be at least 12" (30.5 cm) from the ground or

any object that may be in the path of the exhaust (such as
flowers, rocks or bushes, etc.).

If using an existing vent system, clean lint from the entire length

of the system and make sure exhaust hood is not plugged with

lint. Replace any plastic or metal foil vent with rigid metal or

flexible metal vent.

Verii

■ Cii i

Typical e^diaust installations
Typical installations vent the dryer from the rear of the dryer.
Other installations are possible.

B

B. Elbow
C. Wall
D. Exhaust hood

E. Clamps

F. Rigid metal or flexible metal vent

G. Vent length necessary to connect elbows
H. Exhaust outlet

This dryer can be converted to exhaust out the right side, left

side, or through the bottom. Contact your local dealer to have the
dryer converted.

Optional exhaust installations

AWARNING

M

Fire Hazard

Cover unused exhaust holes with one of the
following kits:

279818 (white)

279915 (graphite)

279925 (biscuit)

Contact your local dealer.

Failure to follow these instructions can result in death,
fire, electrical shock, or serious injury.

C.

Bottom exhaust installation (Not an option

with pedestal installations.)

Alternate installations for close clearances
Venting systems come in many varieties. Select the type best for
your installation. Two close-clearance installations are shown.

Refer to the manufacturer’s instructions.

A. Over-The-Top installation (also available with one

offset elbow)

B. Periscope installation

NOTE: The following kits for close clearance alternate
installations are available for purchase. For further information,
please call 1-800-4-MY-HOME® (1-800-469-4663).

■ Over-The-Top Installation:

Part Number 26-49900