Kenmore ELITE HE4 110.9586 User Manual

Page 7

Attention! The text in this document has been recognized automatically. To view the original document, you can use the "Original mode".

Advertising
background image

■ A level floor vi/lth a maximum slope of 1'' (2.5 cm) under entire

dryer. (If slope is greater than 1" [2.5 cm], install Extended

Dryer Feet Kit, Part No. 279810.) Clothes may not tumble
properly and automatic sensor cycles may not operate

correctly if dryer is not level.

■ For a garage installation, you will need to place the dryer at

least 18" (46 cm) above the floor. If using a pedestal, you will
need an additional

6

* (15.24 cm).

Do not operate your dryer at temperatures below 45°F (7°C). At
lower temperatures, the dryer might not shut off at the end of an

automatic cycle. Drying times can be extended.

The dryer must not be installed or stored in an area where it will

be exposed to water and/or weather.

Check code requirements. Some codes limit, or do not permit,

installation of the dryer in garages, closets, mobile homes, or

sleeping quarters. Contact your local building inspector.

NOTE: No other fuel-burning appliance can be installed in the

same closet as a dryer.

Installation clearances

The location must be large enough to fully open the dryer door.

Dryer Dimensions

Custom undercounter installation - Dryer only

‘Most installations require a minimum 51/2" (14 cm) clearance

behind the dryer for the exhaust vent with elbow. See “Venting
Requirements.”

Minimum installation spacing for recessed area, custom

undercounter or closet installation

The dimensions shown following are for the minimum spacing
allowed.

■ Additional spacing should be considered for ease of

installation and servicing.

■ Additional clearances might be required for wall, door and

floor moldings.

■ Additional spacing of 1" (2.5 cm) on all sides of the dryer is

recommended to reduce noise transfer.

■ For closet installation, with a door, minimum ventilation

openings in the top and bottom of the door are required.

Louvered doors with equivalent ventilation openings are

acceptable.

■ Companion appliance spacing should also be considered.

3"

(7.6 cm)

3"

(7.6 cm)

(0 cm) (80 cm) (0 cm)

A

B

A. Side view - closet or confined area

B. Closet door with vents

Recessed or closet installation - Dryer on pedestal

0

"^<-

27”

a

0

"

■>

(35.6 cm)

^ k18

Y(45.72 cm)

0”l<- 3VA" H 0”

(0 cm) {80 cm) (0 cm)

(0 cm) (68.6 cm) (0 cm)

A

B

A. Recessed area
B. Side view - closet or confined area

Mobile home - additional installation requirements

This dryer is suitable for mobile home installations.
The installation must conform to the Manufactured Home

Construction and Safety Standard, Title 24 CFR, Part 3280
(formerly the Federal Standard for Mobile Home Construction
and Safety, Title 24, HUD Part 280).

Mobile home installations require:

■ Metal exhaust system hardware which is available for

purchase from your local Sears store or Sears Service Center.

■ Mobile home Installation Kit Part Number 346764. See “Tools

and Parts" section for ordering information.

■ Special provisions must be made in mobile homes to

introduce outside air into the dryer. The opening (such as a
nearby window) should be at least twice as large as the dryer
exhaust opening.

Advertising
This manual is related to the following products: