Installation checklist, Check for leaks, Installation instructions (cont’d) – Kenmore POWER MISER 153.330751 User Manual

Page 16

Attention! The text in this document has been recognized automatically. To view the original document, you can use the "Original mode".

Advertising
background image

VENT PIPE TO

OUTDOORS

OR CHIMNEY

Installation Checklist

BEFORE LIGHTING THE PILOT:

• Check the gas lines for leaks.

a. Use a soapy water solution. DO NOT test for gas leaks

using a match or open flame.

b. Brush the soapy water solution on all gas pipes, joints and

flttin».

c. Check for bubbling soap. This means you have a teak.

Turn “OFF” gas and make the necessary repairs.

d. Rccheck for leaks.
e. Rinse off soapy solution and wipe dry.

• Is the new temperature-pressure relief valve properly installed

and piped to an adequate drain? See “Temperature-Pressure
Relief Valve” section.

-

Are the cold and hot water lines connected to the water

heater correctly? See “Water Piping” instructions in the
“Installation Instructions” section.

• Is the water heater completely Ailed with water? See “Filling”

instructions in the “Installation Instructions”.

Will a water leak damage anything? See the “Facts to

Consider About the Location” section.

Is there proper clearance between the water heater and any­

thing that might catch fire? See the “Facts to Consider About

the Location” section.

Do you have adequate ventilation so that the water heater

will operate properly? See “Combustion Air and Ventilation”
in the “Facts to Consider About the Location” section.

Is the draft hood vent piping properly secured? See “Venting”

instructions in the “Installation Instructions” section.

Is there proper clearance between the vent pijie and anything

that might catch on fire? See “Venting” instructions in the
“Installation Instructions” section.

Is the vent pipe properly sloped and does the vent terminate

outdoors? See ' Venting” instructions in the “Installation
Instructions" section.

Do you need to call your gas company to check the gas pipe

and its hookup?

Installation Instructions (cont’d)

CHECK FOR LEAKS

Be sure to check all your gas pipes for leaks before lighting your

water hearer. Use a soapy water solution, not a match or open

flame. Check the factory^ fittings after pilot is lit and gas con­
trol knob is still in “PILOT” position. Then, check the fittings

when the main burner is turned “ON”. Use a soapy water solu­

tion for this, too.

>

\ COLD

UNION SHUTOFF VALVE

DISCHARGE PIPE

(Do not cap or plug)

SHUTOFF .

valve

vfl

TEE

DRIP LEG

(SEDIMENT

TRAP)

6

INCH AIR GAP

-AumMTK ePORpei

water

heatert

MOM. NUMBER

CAP«rTY

1

1

water

HEATER

■QUPPS

PÛR MPUT

ttCOVERY

UAQAL

aSNM. HUWêÉR

1

1

1

QA8 BTUWL

MMOMUM HYDROBTA'nC

lllMWPII 1 iilllN

QN

j

MR.

9A8

PResSUne IN W.C.

HM.IUT laM. BUT NICaUH

hmiiwui

150 j

1 1

PAJ.

WA.

WA. WÆ.

MODEL RATING PLATE

16

Advertising