Troubleshooting, Dryer will not run, No heat – Kenmore 110.8509# User Manual

Page 27: Unusuai sounds, Dryer displaying code message, Ii i, Arming

Attention! The text in this document has been recognized automatically. To view the original document, you can use the "Original mode".

Advertising
background image

TROUBLESHOOTING

First try the solutions suggested here and possibly avoid the cost of a service call..

Dryer will not run

Has a fuse blown, or has a circuit breaker tripped?

There may be 2 fuses or circuit breakers for the dryer. Check
to make sure both fuses are intact and tight, or that both
circuit breakers have not tripped. Replace the fuse or reset
the circuit breaker. If a problem continues, call an electrician.

Is the correct power supply available?
Electric dryers require 240 volt power supply. Check with a
qualified electrician.

Was a regular fuse used?

Use a time-delay fuse.

Is the dryer door firmly closed?

Was the Start button firmly pressed?

Large loads may require pressing and holding the Start
button for 2-5 seconds.

No heat

Has a fuse blown, or has a circuit breaker tripped?

The drum may be turning, but you may not have heat. Electric
dryers use 2 fuses or circuit breakers. Replace the fuse or

reset the circuit breaker. If a problem continues, call an
electrician.

Unusuai sounds

Has the dryer had a period of non-use?
If the dryer hasn’t been used for a while, there may be a

thumping sound during the first few minutes of operation.

Is a coin, button, or paper clip caught between the drum
and front or rear of the dryer?
Check the front and rear edges of the drum for small objects.
Clean out pockets before laundering.

Are the four legs installed, and is the dryer level front to

back and side to side?

The dryer may vibrate if not properly installed. See the

Installation Instruotions.

Is the clothing knotted or balled up?
When balled up, the load will bounce, causing the dryer to
vibrate. Separate the load items and restart the dryer.

Dryer displaying code message

“PF” (power failure), check the following:
Was the drying cycle interrupted by a power failure?
Press and hold START to restart the dryer.

“E” Variable (E1, E2, E3) service codes:
Call for service.

Clothes are not drying satisfactorily, drying times are too
long, or load is too hot

Is the lint screen clogged with lint?
Lint screen should be cleaned before each load.

ii

I

Fire Hazard

Use a heavy metal vent.

Do not use a plastic vent.

Do not use a metai foil vent

Failure to follow these instructions can result in death
or fire.

Is the exhaust vent or outside exhaust hood clogged with
lint, restricting air movement?
Run the dryer for 5-10 minutes. Hold your hand under the
outside exhaust hood to check air movement. If you do not

feel air movemenf, clean exhaust system of lint or replace
exhaust vent with heavy metal or flexible metal vent. See

“Venting Requirements” in the Installation Instructions.

Are fabric softener sheets blocking the grille?

Use only one fabric softener sheet, and use it only once.
Is the exhaust vent the correct length?
Check that the exhaust vent is not too long or has too many

turns. Long venting will increase drying times. See “Plan Vent
System” in the Installation Instructions.

Is the exhaust vent diameter the correct size?
Use 4" (10.2 cm) diameter vent material.

ARMING

Explosion Hazard

Keep flammable materials and vapors, such as
gasoline, away from dryer.

Place dryer at least 18 inches (46 cm) above the floor

for a garage instaliation.

Failure to do so can result in death, explosion, or fire.

Is the dryer located in a room with temperature below
45“F {7°C)7
Proper operation of dryer cycles requires temperatures above
45°F (7°C).

27

Advertising
This manual is related to the following products: