AWARNING

J

Dryer Dimensions

U/

Explosion Hazard

Keep flammable materials and vapors, such as
gasoline, away from dryer.

Place dryer at least 18 inches (46 cm) above the floor

for a garage installation.

Failure to do so can result in death, explosion, or fire.

You wiii need
■ A location that allows for proper exhaust installation. See

“Venting Requirements."

■ A separate 30-amp circuit.

■ If using a power supply cord, a grounded electrical outlet

located within 2 ft (61 cm) of either side of the dryer. See
“Electrical Requirements.”

■ A sturdy floor to support the total dryer weight of 200 lbs

(90.7 kg). The combined weight of a companion appliance
should also be considered.

■ A level floor with a maximum slope of 1" (2.5 cm) under entire

dryer. (If slope is greater than 1" [2.5 cm], install Extended
Dryer Feet Kit, Part Number 279810.) Clothes may not tumble
properly and automatic sensor cycles may not operate
correctly if dryer is not level.

■ For a garage installation, you will need to place the dryer at

least 18" (46 cm) above the floor. If using a 13" (33 cm)
pedestal, you will need to place the pedestal at least
6" (15.2 cm) above the floor. If using a 15.5" (39.4 cm)
pedestal, you will need to place the pedestal at least

3" (7.6 cm) above the floor.

Do not operate your dryer at temperatures below 45“F (7°C). At
lower temperatures, the dryer might not shut off at the end of an
automatic cycle. Drying times can be extended.

The dryer must not be installed or stored in an area where it will

be exposed to water and/or weather.

Check code requirements. Some codes limit, or do not permit,
installation of the dryer in garages, closets, mobile homes, or
sleeping quarters. Contact your local building inspector.

Installation clearances

The location must be large enough to allow the dryer door to
open fully.

*Most installations require a minimum 5y2" (14 cm) clearance

behind the dryer for the exhaust vent with elbow. See “Venting
Requirements.”

Minimum installation spacing for recessed area, custom
undercounter or closet installation

The following dimensions shown are for the minimum spacing
allowed.

■ Additional spacing should be considered for ease of

installation and servicing.

■ Additional clearances might be required for wall, door and

floor moldings.

■ Additional spacing of 1" (2.5 cm) on all sides of the dryer is

recommended to reduce noise transfer.

■ For closet installation, with a door, minimum ventilation

openings in the top and bottom of the door are required.
Louvered doors with equivalent ventilation openings are
acceptable.

■ Companion appliance spacing should also be considered.

Custom undercounter installation - Dryer only

‘Additional spacing recommended