WIRE AND MOUNT THERMOSTAT (continued)

Recheck for level position­

ing, and firmly tighten both

mounting screws.

If installing CT50A, CT51 A,
or CT52A, make sure you
have the current (anticipator
setting) for your system. This is

the number you wrote in the box

in step 3. If you were unable to

find the current draw for step 3,

this

information

can

be

found

printed on the primary control at
the furnace. The primary control

is usually a gas valve, zone valve,
or a relay or burner control box

with the thermostat wires con­

nected to it.

jncfi

OIL BURNER CONTROL

On the CT50A, CT51A, or

CT52A, set heat anticipator

indicator at rating printed on
primary control.

CHECKOUT

THE

THERMOSTAT

On the CT51A, the system

switch controls as follows:

HEAT—heating system only

operates.

. OFF—heating and cooling sys­

tems are disconnected.

COOL—cooling system only

operates.

The

fan

switch

controls

as

follows:

AUTO—fan

operates

when

heating or cooling system,

operates.

ON—fan

operates

continu­

ously.

NOTE: In the following instruction,

disregard

heating

or

cooling

directions if not applicable to

your system.

Turn

on

power

to

the

heating/cooling system.

Observe system operation

for at least one cycle on

both heating and cooling. To
observe:

Place the system switch

at HEAT position and fan

switch at AUTO. More the temper­

ature setting lever 10 F [5.6 C]
above

room

temperature.

The

heating

equipment

should

turn

on, A short warm-up period may
be required before the system
fan turns on.

Place system switch at
COOL position and move
temperature setting lever 10 F
[5.6 C[ below room temperature.

The

cooling

equiprnent

should

turn on and the system fan should
turn on,

NOTE: Some systems have a time

delay that can prevent opera­

tion up to 30 seconds.

Turn the fan switch to ON.

The system fan should turn

on,

and

operate

continuously.

The system blower should con­

tinue to operate at any system

switch or thermostat setting.

THERMOSTAT

SETTING

On CT51A, place the sys­

tem and fan switches at

the desired settings for operation.

On all models, move the

temperature setting lever

to the desired temperature com­
fort level.

(See ill

4 to hf

heat a|

Press the thermostat cover

firmly onto the mounting