USE AND CARE

NEVER store a spare LP tank under or near griil or in

enclosed areas

m

• Never fill the cylinder beyond 80% full.

• An overfilled or improperly stored tank is a hazard due

to possible gas release from the safety relief valve.

• If you see, smell or hear escaping gas, immediately get

away from the LP tank/grill and call your fire

department.

• if the above is not followed exactly, a fire causing

death or serious injury may occur.

LP Tank Removal, Transport And Storage

• Turn OFF all control knobs and LP tank valve. Turn coupling

nut counterclockwise by hand only - do not use tools to
disconnect. Lift LP tank wire upward off of LP tank collar, then

lift LP tank up and off of support bracket. Install safety cap onto
LP tank valve. Always use cap and strap supplied with valve.

Failure to use safety cap as directed may result in serious

personal injury and/or property damage.

LP Tank Valve

Safety

Cap

Retainer Strap

• A disconnected LP tank in storage or being transported must

have a safety cap installed (as shown). Do not store an LP tank
in enclosed spaces such as a carport, garage, porch, covered
patio or other building. Never leave an LP tank inside a vehicle

which may become overheated by the sun.

• Do not store an LP tank in an area where children play.

4.464810408

• The LP cylinder used with your griil must meet the

following requirements:

• Use LP cylinders only with these required measurements: 12"

(30.5cm) (diameter) x 18" (45.7 cm) (tall) with 20 lb. (9 kg.)
capacity maximum.

• LP cylinders must be constructed and marked in accordance

with specifications for LP cylinders of the U.S. Department of

Transportation (DOT) or for Canada, CAN/CSA-B339,
cylinders, spheres and tubes for transportation of dangerous
goods. Transport Canada (TC). See LP cylinder collar for

marking.

__

• LP cylinder valve must have:

• Type 1 outlet compatible with

regulator or grill.

• Safety relief valve.

_

_

• UL listed Overfill Protection

OPD Hand Wheel

Device (OPD). This OPD safety

feature is identified by a unique triangular hand wheel. Use

only LP cylinders equipped with this type of valve.

• LP cylinder must be arranged for vapor withdrawal and include

collar to protect LP cylinder valve. Always keep LP cylinders in

upright position during use, transit or storage.

LP Cylinder

LP cylinder in upright position for vapor withdrawal

LP (Liquefied Petroleum Gas)

• LP gas is nontoxic, odorless and colorless when produced. For

Your Safety, LP gas has been given an odor (similar to rotten

cabbage) so that it can be smelled.

• LP gas is highly flammable and may ignite unexpectedly when

mixed with air.

LP Cylinder Filling

• Use only licensed and experienced dealers.

• LP dealer must purge new cylinder before filling.

• Dealer should NEVER fill LP cylinder more than 80% of LP

cylinder volume. Volume of propane in cylinder will vary by

temperature.

• A frosty regulator indicates gas overfill. Immediately close LP

cylinder valve and call local LP gas dealer for assistance.

• Do not release liquid propane (LP) gas into the atmosphere.

This is a hazardous practice.

• To remove gas from LP cylinder, contact an LP dealer or call a

local fire department for assistance. Check the telephone

directory under “Gas Companies” for nearest certified LP
dealers.

Advertising