Owner’s manual, Troubleshooting, Continued – Desa Tech CGG2618P User Manual

Page 21

Advertising
background image

21

103425

OWNER’S MANUAL

TROUBLESHOOTING

Continued

IMPORTANT:

Operating heater where impurities in air exist may create odors. Cleaning

supplies, paint, paint remover, cigarette smoke, cements and glues, new carpet or textiles,
etc., create fumes. These fumes may mix with combustion air and create odors. These odors
will disappear over time.

OBSERVED PROBLEM

Heater produces a clicking/ticking noise
just after burners are lit or shut off

Heater produces unwanted odors

Heater shuts off in use (ODS operates)

Gas odor even when control knob is in OFF
position

Gas odor during combustion

Log set cycles to pilot, but room tempera-
ture drops to a lower than ideal level before
log set comes back on

POSSIBLE CAUSE

1. Metal expanding while heating or con-

tracting while cooling

1. Heater burning vapors from paint, hair

spray, glues, cleaners, chemicals, new
carpet, etc. (See

IMPORTANT

state-

ment above)

2. Low fuel supply
3. Gas leak.

See Warning statement at

top of page

1. Not enough fresh air is available
2. Low line pressure
3. ODS/pilot is partially clogged

1. Gas leak.

See Warning statement at

top of page

2. Control valve defective

1. Foreign matter between control valve

and burner

2. Gas leak.

See Warning statement at

top of page

1. Thermostat sensing bulb needs to be re-

positioned

REMEDY

1. This is common with most heaters. If

noise is excessive, contact qualified ser-
vice person

1. Open window to ventilate room. Stop us-

ing odor causing products while heater
is running

2. Refill supply tank
3. Locate and correct all leaks (see

Checking Gas Connections, page 13)

1. Open window and/or door for ventilation
2. Contact local propane/LP gas company
3. Clean ODS/pilot (see Cleaning and

Maintenance, page 18)

1. Locate and correct all leaks (see

Checking Gas Connections, page 13)

2. Replace control valve

1. Take apart gas tubing and remove for-

eign matter

2. Locate and correct all leaks (see

Checking Gas Connections, page 13)

1. Reposition thermostat sensing bulb (see

Instructions for Optional Positioning of
Thermostat Sensing Bulb,
page 23)

WARNING: If you smell gas

• Shut off gas supply.
• Do not try to light any appliance.
• Do not touch any electrical switch; do not use any phone in your

building.

• Immediately call your gas supplier from a neighbor’s phone. Follow the

gas supplier’s instructions.

• If you cannot reach your gas supplier, call the fire department.

www.desatech.com

Advertising
This manual is related to the following products: