Installation Instructions

and

RENEWAL PARTS IDENTIFICATION

PF411-10

161-048940-001

FEBRUARY, 2001

(Supersedes PF411-9)

© 2010 Chromalox®, Inc.

Portable Unit Blower Air Heater — Type HF

Figure 1

Model

Model

Volts

Watts

Amps

Wiring

Plug

Number

Fig. No.

Fig. No.

HF203G AC

C

120V1P

1,900

15.8

6

3

HF203G AC

C

240V1P

2,000

8.3

6

4

HF303H AC*

C

120V1P

3,000

25.0

7

HF303G AC

C

240V1P

3,000

12.5

7

3

HF403G AC

C

240V1P

4,000

16.7

7

5

HF203EG DC

E

120V1P

1,900

15.8

9

3

HF203DG DC

E

240V1P

2,000

8.3

8

4

HF303E DC*

E

120V1P

3,000

25.0

12

HF303DG DC

E

240V1P

3,000

12.5

11

4

HF403E DC**

E

240V1P

4,000

16.7

11

Specifications - Table A

* Cord Only, no plug.
** Without Cord and plug.

GENERAL

Hazard of Fire or Discoloration of Temperature
Sensitive Fabrics. Keep combustible material and
such fabrics away from heater. Do not operate
heater where flammable vapors, gases or liquids
are present. Heaters should not be operated in
room temperatures above 80˚F.

Hazard of Electric Shock. Any installation involving
electric heaters must be effectively grounded in
accordance with the National Electrical Code. Use
the required polarized wall receptacle that mates
with the appropriate plug, referenced in Table A,
shown in Figures 3, 4 or 5 (see Page 2).

T o a v o i d p e r s o n a l i n j u r y r e a d “ I M P O R T A N T
INSTRUCTIONS” on page 3 before installation or
operation of heater.