Wl6000 series – Campbell Hausfeld WL6000 User Manual

Page 7

Advertising
background image

WL6000 Series

7

Operating Instructions

Troubleshooting Chart (Continued)

Symptom

Possible Cause(s)

Corrective Action

1. Loose connections (fittings, tubing,

etc.)

2. Loose drain cock

3. Check valve leaking

1. Clogged intake filter

2. Air leaks in piping (on machine or in

outside system)

3. Broken inlet valves

4. Piston ring broken

5. Cylinder or piston ring is worn or

scored

1. Excessive water in tank

2. High humidity

1. Defective pressure switch

2. Excessive air usage

1. Excessive condensation in tank

2. Air leaks in piping (on machine or in

outside system)

3. Tank check valve leaking

Check valve stuck in an open position

1. Check all connections with soap and water solution

and tighten

2. Tighten

3. Disassemble check valve assembly, clean or replace

Do not disassemble check valve

with air in tank; bleed tank

1. Clean or replace

2. Replace leaking components or tighten as necessary

3. Have authorized service representative repair unit

4. Replace

5. Replace

1. Drain tank

2. Move to area of less humidity; use air line filter

1. Replace switch

2. Decrease air usage; compressor not large enough for

air requirement

1. Drain more often

2. Replace leaking components or tighten as necessary

3. Replace or repair as necessary

Do not disassemble check valve

with air in tank; bleed tank

Remove and replace check valve

Do not disassemble check valve

with air in tank; bleed tank

Tank pressure drops
when compressor shuts
off

Air output lower than
normal/low discharge
pressure

Excessive moisture in
discharge air

Compressor runs
continuously

Excessive starting and
stopping (auto start)

Air leaking from
unloader on pressure
switch

Advertising