Operating clearances, Service clearances, Controls – Cleveland Range SteamChef (2) 22CGT3 User Manual

Page 2: Approvals, Electrical, Cold water, Drain connection

Advertising
background image

(NOT TO SCALE)

SECT.

B

PAGE

16

0707

Litho in U.S.A.

NOTES:

Cleveland Range reserves right of design improvement or modification, as warranted.
Many regional, state and local codes exist and it is the responsibility of the owner and installer to comply with the codes.
Cleveland Range equipment is built to comply with applicable standards for manufacturers. Included among those approval agencies are U.L/NSF#4 and CSA (AGA, CGA).

25.50"

648mm

29.25"

743mm

2.68"

68mm

38.84"

987mm

92º

90º

54.94"

1395mm

25.50"

648mm

29.25"

743mm

2.68"

68mm

38.84"

987mm

92º

90º

54.94"

1395mm

25.50"

648mm

29.25"

743mm

2.68"

68mm

38.84"

987mm

92º

90º

54.94"

1395mm

65.06"

1653mm

25.50"

648mm

38.84"

987mm

38.84"

987mm

38.93"

989mm

61.60"

1565mm

25.75"

654mm

20.11"

511mm

16,41"

417mm

8.49"

21.6mm

2.68"
68mm

2.02"
51mm

4.68"
119mm

4.83"
123mm

4.83"
123mm

2.02"
51mm

2.02"
51mm

61.60"

1565mm

25.79"

655mm

20.11"

511mm

16.40"

417mm

8.39"

21.3mm

2.68"
68mm

61.63"

1565mm

25.79"

655mm

20.11"

511mm

16,41"

417mm

8.38"

213mm

3.26"

83mm

2.64"
67mm

43.57"

1107mm

7.73"

196mm

65.06"

1653mm

25.50"

648mm

43.57"

1107mm

7.73"

196mm

65.06"

1653mm

25.50"

648mm

43.57"

1107mm

7.73"

196mm

C

C1

C

C2

D

G

G

C

C1

C

C2

D

G

G

C

C1

C

C2

D

G

G

C

C1

C

C2

D

G

G

C

C1

C

C2

D

G

G

C

C1

C

C2

D

G

G

C

C1

C

C2

D

G

G

C

C1

C

C2

D

G

G

C

C1

C

C2

D

G

G

C

C1

C

C2

D

G

G

C

C1

C

C2

D

G

G

C

C1

C

C2

D

G

G

OPERATING CLEARANCES

3" Left, 3" Right and 3" Rear.

SERVICE CLEARANCES

12" on control side. Contact factory for variances to clearances.

CONTROLS

(per compartment)

60-minute electro mechanical timer with load compensating feature.

Three function control switch for Timed Cooking and Continuous Steaming.

APPROVALS

UL - Gas, UL - Sanitation (NSF Standards)

GAS

(one connection per unit)

1/2” Dia. IPS

45,000 & 62,000 BTU’s

S

SU

UP

PP

PL

LY

Y P

PR

RE

ES

SS

SU

UR

RE

E: NATURAL - 4.00’ W.C. minimum, 14.00” W.C. maximum

PROPANE - 12.00” W.C. minimum, 14.00” W.C. maximum

Manufacturer must be notified if unit will be used above 2,000 ft. altitude.

ELECTRICAL

(one connection per unit)

115V, 1 Phase, 35 Watts.

COLD WATER

C

C1

1: Condensing Water Inlet, 35 Psi Minimum, 60 Psi Maximum.

C

C2

2: Fill Water Inlet, 35 Psi Minimum, 60 Psi Maximum.

Two 3/4" NH-F (Garden Thread) connections. Use NSF approved hose.

DRAIN CONNECTION

1" NPT-M

Do not connect other units to this drain.

Drain line must be vented. Vented drain connection included.

Do not connect drain to PVC pipe.

H

D

C

C1 C2

H

D

C

C1 C2

Top compartment has capacity for:

Three, 12" x 20" x 21⁄2" deep Cafeteria Pans

or

Six, 12" x 20" x 1" deep Cafeteria Pans.

or

Two, 12" x 20" x 4" deep Cafeteria Pans

Bottom compartment has capacity for:

Six, 12" x 20" x 21⁄2" deep Cafeteria Pans.

or

Twelve, 12" x 20" x 1" deep Cafeteria Pans.

or

Four, 12" x 20" x 4" deep Cafeteria Pans