CyberPower Systems PP1500 User Manual

Safety warnings, Installing your ups system, Basic operation

Advertising
background image

Professional Tower UPS

PP1500/PP2200

User Manual

SAFETY WARNINGS

(SAVE THESE INSTRUCTIONS)

This manual contains important safety instructions. Please read and follow all instructions carefully during installation and operation of the unit.
Read this manual thoroughly before attempting to unpack, install, or operate your UPS.
This equipment can be operated by any individuals with no previous training.
The socket-outlet shall be installed near the equipment and easily accessible.
During the installation of this equipment it should be assured that the sum of the leakage currents of the UPS and the connected loads does not
exceed 3.5mA.
Attention, hazardous through electric shock. Also with disconnection of this unit from the mains, hazardous voltage still may be accessible
through supply from battery. The battery supply should be therefore disconnected in the plus and minus pole at the quick connectors of the
battery when maintenance or service work inside the UPS is necessary.
Do not dispose of batteries in a fire, the battery may explode.
Do not open or mutilate the battery or batteries, released electrolyte is harmful to the skin and eyes.

INSTALLING YOUR UPS SYSTEM

UNPACKING


Inspect the UPS upon receipt. The box should contain the following:

UPS Unit x1; PowerPanel Business Edition Software Disk x1; Serial Interface Cable (DB-9) x1; USB Device Cable x1;Telephone Cable x1;

HOW TO DETERMINE THE POWER REQUIREMENTS OF YOUR EQUIPMENT


1. Insure that the equipment plugged into the battery power-supplied outlets does not exceed the UPS unit’s rated capacity (1500VA/1000W for

PP1500, 2200VA/1500W for PP2200). If rated unit capacities are exceeded, an overload condition may occur and cause the UPS unit to
shut down or the circuit breaker to trip.

2. If the power requirements of your equipment are listed in units other than Volt-Amps (VA), convert Watts (W) or Amps (A) into VA by doing

the calculations below. Note: The below equation only calculates the maximum amount of VA that the equipment can use, not what is
typically used by the equipment at any one time. Users should expect usage requirements to be approximately 60% of below value.

TO ESTIMATE POWER REQUIREMENTS

1. Watts (W) x 2.0 = VA or Amps (A) x 120 = VA

2. Add the totals up for all pieces of equipment and multiply this total by 0.6 to calculate actual requirements. There are many factors that can

affect the amount of power that your computer system will require. The total load that you will be placing on the battery-powered outlets
should not exceed 80% of the unit’s capacity.

HARDWARE INSTALLATION GUIDE

1. Connect the equipment to your UPS outlets. Items such as copiers, laser printers, vacuums,

space heaters, paper shredders, or other large electrical devices should not be connected to
the UPS. Please assure that the total loads of your equipments must be less than the
maximum total power load of your UPS.


2. Connect your UPS power cord into a two-pole, three-wire grounding receptacle only. Please

avoid using extension cords and adapter plugs. (To maintain optimal battery charge, leave
the UPS plugged in at all times.)



3. Press the UPS power button to turn it on. The “Power On” indicator will be illuminated in

“Green”.


4. Install your optional software and accessories. To use the software, simply connect the enclosed serial interface cable to the serial port on

the UPS and an open serial port on the computer.


BASIC OPERATION


FRONT PANEL DESCRIPTION


Power Switch


Press the ON/OFF button to turn the UPS on or off.

Test Switch

This UPS performs a self-test automatically when power is on. If the UPS passes the test, it
returns to on-line operation. If the UPS fails the self-test, please recharge the battery for 4
hours and perform another self-test. If it fails after recharging the battery, please replace the
battery.


Battery Indicators


These indicators show a visual indication of the battery charge. If battery capacity is under 20%, no indicator LED will
illuminate and the UPS starts beeping.


Load Level Indicators


These LED indicators show a visual depiction of the UPS load. The load indicator LED will turn orange if the load is
between 80 and 100%. If the load is under 20%, no indicator LED will illuminate.



Wiring Fault Indicator

This LED indicator will illuminate to warn the user that a wiring problem exits with the AC outlet, such as bad ground, miss
ground or reversed wiring. If this is illuminated, the user is advised to disconnect all electrical equipment from the outlet and
have an electrician check the outlet to insure proper wiring.

Using Battery Indicator


This illuminates during utility failure, indicating that the battery is supplying power to the battery-power supplied outlets.


AVR Indicator

This LED indicates that the UPS is operating in automatic voltage regulation mode. When the LED is illuminated continuously,
it indicates input over-voltage and the UPS unit bucks the voltage. When the LED is flashed in rotation, it indicates that the
UPS unit is boosting input voltage.

Power On Indicator


This LED is illuminated when the utility condition is normal and the UPS outlets are providing “clean power”, free of surges and
spikes.









REAR PANEL DESCRIPTION

Backup Power for Critical Loads

The UPS provides 2 battery powered, surge protected outlets for the most critical connected equipments
and insures temporary uninterrupted operation of connected equipments during a power failure.
NOTE: When the UPS is overloaded, the UPS will interrupt power supply to the other 6 battery
outlets and leave these 2 outlets for critical loads uninterrupted.


Battery Backup and Surge Protection Outlets

This unit provides 6 battery-powered, surge-protected and AVR outlets for connected equipments and
insures uninterrupted operation of connected equipment during a power failure.


Circuit Breaker Reset for Overload Protection

Re-settable circuit breakers provide optimal overload protection.

Communication Protection Ports


Ethernet RJ-45 Network Protection Ports protect your Phone, Fax and Modem from surges over the Ethernet/Phone line.



Serial/ USB Ports

The PP1500/PP2200 provides two serial and one USB ports to allow connection and communication between the UPS and two computers.
This allows the simultaneous shutdown of two computer systems. These interfaces are also compatible with the UPS service provided by
Windows 2000, Windows NT, Windows XP, Windows Server 2003.



1. The Primary PC

To control the UPS and make any change to the operation of the UPS,

please install the PowerPanel Business Editon in your primary computer and
then connect it to the Serial Port I or USB port of the UPS.



2. The Secondary PC

The secondary computer with PowerPanel installed should be connected to

the serial port II. This PC will shutdown following the user settings in
PowerPanel Software when a power failure occurs but it is unable to exhibit any
control over the UPS.

When power failure occurs, one of the following shutdown sequences will be executed:

1. If the Primary and Secondary serial ports are both in use: the Primary computer will start to count down (user controlled delay) for shutdown

(User Control delay can be set in the PowerPanel Business Edition Recommended time is 5 minutes). Once the Primary computer is shutdown,
the UPS will signal the Secondary computer and initiate the Secondary to shutdown. The UPS default shutdown time is 2 minutes. Therefore,
it is recommended that Secondary computer is set to shutdown within 1 minute in PowerPanel Software.

2. If only the Secondary serial port is in use: the Secondary computer will shutdown following the user settings in PowerPanel Software.

However, the Secondary computer will not able to signal the UPS to shutdown. Therefore, the UPS will only power off when it is in low
battery.

BATTERY REPLACEMENT AND STORAGE


Contact your dealer or call the number in this manual for information on battery replacement.

Read and follow the

IMPORTANT SAFETY INSTRUCTIONS before servicing the battery. Service the battery under the supervision of

personnel knowledgeable of batteries and their precautions. Keep unauthorized personnel away from batteries.

CAUTION!
Use only the specified type of battery. See your dealer for replacement batteries.
CAUTION! The battery may present the risk of electrical shock. Do not dispose of batteries in a fire, as it may explode. Follow all local
ordinances regarding proper disposal of batteries.
CAUTION! Do not open or mutilate the batteries. Release electrolyte is harmful to the skin and eyes and may be toxic.
CAUTION! A battery can present a high risk of short circuit current and electric shock. Take the following precautions before replacing the
battery:
1. Remove all watches, rings or other metal objects.
2. Only use tools with insulated handles.
3. DO NOT

lay tools or other metal parts on top of battery or any battery terminals.

4. Wear rubber gloves and boots.
5. Determine if the battery is inadvertently grounded. If inadvertently grounded, remove source of ground.

CONTACT WITH A GROUNDED

BATTERY CAN RESULT IN ELECTRICAL SHOCK! The likelihood of such shock will be reduced if such grounds are removed during
installation and maintenance (applicable to a UPS and a remote battery supply not having a grounded circuit).

BATTERY REPLACEMENT PROCEDURE:


1. Turn off and unplug all connected equipments.
2. Turn the UPS off and unplug it from the AC power source.
3. Carefully turn the UPS upside down. Remove the 6 retaining screws and the

cover.

4. Disconnect the black and red wires from the battery set.
5. Remove the battery protection cover and take out the battery set from the

compartment.

6. Slide a new battery pack into the unit. Assemble the battery protection cover,

cable, screws in the reverse sequence of above steps.


REMINDER
: Recharge the unit for 4 – 8 hours to ensure the UPS performs
expected runtime

STORAGE:
First turn off your UPS and disconnect its power cord from the wall outlet. Disconnect all cables connected to the UPS to avoid battery drain. To
store your UPS for an extended period, cover it and store with the battery fully charged. Recharge the battery every three months to insure
battery life. If the battery remains uncharged for an extended period of time, it may suffer permanent loss of capacity.

TROUBLE SHOOTING

Problem

Possible Cause

Solution

The UPS does not perform
expected runtime.

Batteries are not fully charged.

Recharge the battery by leaving the UPS plugged in.

Battery is slightly worn out.

Contact CyberPower Systems at [email protected].

The UPS will not turn on.

The on/off switch is designed to
prevent damage by rapidly
turning it off and on.

Turn the UPS off.
Wait 10 seconds and then turn the UPS on.

The unit is not connected to an
AC outlet.

The unit must be connected to a 110/120v 60Hz outlet.

The battery is worn out.

Contact CyberPower Systems at [email protected].

Mechanical problem.

Contact CyberPower Systems at [email protected].

Outlets do not provide
power to equipment

Circuit breaker is tripped due to
overload

Turn the UPS off and unplug at least one piece of equipment. Wait 10
seconds, reset the circuit breaker and then turn the UPS on.

Batteries are discharged

Allow the unit to recharge for at least 4 hours.

Unit has been damaged by a
surge or spike.

Contact CyberPower Systems at [email protected].

PowerPanel Business Edition
is inactive (all icons are gray).

The serial cable is not
connected.

Connect the serial cable to the UPS unit and an open serial port on the back
of the computer. You must use the cable that came with the unit.

The serial cable is connected to
the wrong port.

Check the back of the computer for an additional serial port. Move the
cable to this port.

The unit is not providing battery
power.

Shutdown your computer and turn the UPS off. Wait 10 seconds and turn the
UPS back on. This should reset the unit.

The serial cable is not the cable
that was provided with the unit.

You must use the cable that was included with the unit for the software and
the unit to be able to communicate.

(2)

(1)

(3)

(4)

User Manual x1

Please go to www.cyberpowersystems.com for free download PowerPanel Software.

K01-P1K50H0-01

BATTERY

CAPACITY

LOAD

CAPACITY

Advertising
This manual is related to the following products: