Operating procedure to transmit, Operator troubleshooting – Uniden MC-4300 User Manual

Page 4

Attention! The text in this document has been recognized automatically. To view the original document, you can use the "Original mode".

Advertising
background image

6. To receive a weather information broadcasting, set CB WX Switch to WX position.

Then, select either WX1 (156.8 MHz), WX2(156.375 MHz) by setting the switch
located next to it to a desired position.

OPERATING PROCEDURE TO TRANSMIT

CAUTION --------------------------------------------------

The transmitter Voltage Standing Wave Ratio {V.S.W. R.) measurement must
be performed prior to the use of the transmitter. A V.S.W.R. ratio in excess

of 2:1 may damage the transmitter.

1. Be sure the operator has read and understands D.O.C. Rules and Regulations prior

to operating the transmitter.

2. Select the desired channel,

3. If the channel is clear, depress the push-to-talk switch on the microphone and

speak in a normal voice.

OPERATOR TROUBLESHOOTING

Should the unit malfunction or not perform properly, the operator should perform

the procedures indicated below:

1. If the transceiver is completely inoperative.

* Check the power cord and fuse.

2. If trouble is experienced with receiving.

* Check ON/OFF VOLUME CONTROL setting.
* Be sure SQUELCH is adjusted properly. Is the radio over-squelched?
* Check to see that the radio is switched to an operational mode.

3. If trouble is experienced with transmitting.

* Check to see that the transmission line (coaxial cable) is securely connected to

the ANTENNA CONNECTOR.

* Be sure that the antenna is fully extended for proper operation.
* Be sure that all transmission line (coaxial cable) connections are secure and free

of corrosion.

- 3 -

Advertising