Operating Instructions and Parts Manual

Troubleshooting Chart

www.chpower.com

Symptom

Possible Cause(s)

Corrective Action

Compressor will not run

1 . Switch in OFF position

1 . Make sure compressor is plugged in and

switch is ON

2 . No electrical power at wall outlet

2 . Check circuit breaker or fuse at electrical

panel

3 . Compressor has reached automatic shut-

off pressure

3 . Release air from tank until compressor

restarts automatically

4 . Motor overheated/overworked

4 . Switch unit to OFF, wait 30 minutes to cool,

turn ON again to resume work . Make sure
compressor is run in a clean, well-ventilated
area where temperature will not exceed
100°F .

5 . Loose electrical connection

5 . Check all electrical connections

6 . ON / OFF switch bad

6 . Replace ON / OFF switch

7 . Pressure switch bad

7 . Replace pressure switch

8 . Defective motor

8 . Replace pump / motor assembly

Thermal overload protector
cuts out repeatedly

1 . Lack of proper ventilation/room

temperature too high

1 . Move compressor to a clean, well ventilated

area where temperature will not exceed
100°F .

2 . Excessive air usage, compressor too small 2 . Decrease usage or purchase unit with higher

air delivery (SCFM)

Tank pressure drops when
compressor shuts off

1 . Open tank drain valve

1 . Close tank drain valve

2 . Loose connections (fittings, tubing, air

hose, any connections, etc .)

2 . Check all connections with soap and water

solution . If a leak is detected, tighten .
Or remove fitting and apply pipe tape to
threads and reassemble .

Do not disassemble check

valve. With air in tank,

bleed tank first.

3 . Tank leaks

3 . Check entire tank for leaks with soap and

water solution .

Compressor runs
continuously / air output
lower than normal

1 . Excessive air usage, compressor too small 1 . Decrease usage or purchase unit with higher

air delivery (SCFM)

2 . Open tank drain valve

2 . Close tank drain valve

3 . Loose connections (fittings, tubing, air

hose, any connections, etc .)

3 . Check all connections with soap and water

solution . If a leak is detected, tighten .
Or remove fitting and apply pipe tape to
threads and reassemble .

4 . Pump wore out

4 . Replace pump / motor assembly

Excessive moisture in
discharge air

1 . Excessive water in tank

1 . Drain tank, tilt tank to remove moisture

2 . High humidity

2 . Move to area of less humidity; use air line

filter

Safety valve pops open

1 . Defective pressure switch

1 . Replace pressure switch

2 . Defective safety valve

2 . Replace safety valve with genuine

replacement part