Installation instructions, Technical data – Cannon Carrick C60GCIS User Manual

Page 31

Advertising
background image

31

TECHNICAL DATA

Gas connection

Rp ½ (½" BSP female)

Pressure test point

Front left hotplate injector

Gas rate adjustment

None

Aeration adjustment

None

Electrical connection

Flexible cord fitted with a 3 pin 13 amp plug

230/240V a.c. 50Hz. 13A fuse.

INSTALLATION INSTRUCTIONS

G20 at 20mbar

G30 at 28-30mbar

G31 at 37mbar

BURNER

HEAT INPUT

INJECTOR

HEAT INPUT

INJECTOR

HOTPLATE

Front Left and Rear Right

3.05 kW

116

3.0 kW (220g/h)

86

HOTPLATE

Front Right and Rear Left

2.0 kW

103

2.0 kW (145g/h)

70

Grill

3.7 kW

150

3.4 kW (200g/h)

91

Main Oven

2.5 kW

115

2.3 kW (165g/h)

71

Top Oven

1.9 kW

100

1.9 kW (135g/h)

66

Advertising