® TAPE END OUT terminal

Signal output terminal to annunciate to other devices that

the tape has run out on the VCR.

@ REC TRIGGER OUT terminal

Signal output terminal to control the switching interval of

the video cameras when connected to a sequential

switcher or multiplexer.

@ ALARM OUT terminal

Output terminal to transmit an alarm signal to peripheral

equipment.

® ALARM RESET terminal

Input terminal to reset alarm recording.

Alarm recording is reset when this terminal is connected to

the ground terminal during recording.

ALARM IN terminal

Input terminal to start alarm recording.

The VCR goes into alarm recording mode when this

terminal is connected to the ground terminal while in the

record mode, record pause mode, or stop mode.

Ce) ALL CLEAR button

Pressing this button will clear the entire time-date, and

timer program memory The power will be turned off at the

same time. Pressing the

POWER button will restore

power

@ REMOTE IN jack

Input jack for optional wired remote control.

® MIC IN jack

Input jack for audio signals from a microphone. The RCA

jack input (audio input) is automatically switched off when

this jack is utilized.

® VIDEO IN connector (BNC)

Input connector tor video signal. Connect with an externaf

video source such as a video camera, etc.

m VIDEO OUT connector (BNC)

Output connector for video signal. Connect with a monitor

TV.

® AUDIO IN jack (RCA type)

Input jack for audio signal. Connect with an external audio

source.

® AUDIO OUT jack (RCA type)

Output jack for audio signal. Connect with an externaf

audio equipment.

® ONE SHOT IN terminal

Input terminal to start one shot recording.

The VCR goes into one shot recording mode when this

terminal is connected to the ground terminal while in the

L01, L02 or L03 record mode.

Notes: ----------------------------------------------------------------

> ALL CLEAR button

Do not use this function (ALL CLEAR) frequently.

Press this button only when an abnormality (ex. VCR

display does not turn ON.) occurs.

When this button is pressed, the power turns OFF and

each data stored (ex. dock, timer program, etc.) is cleared

and returns to the initial setting status. It will be necessary

to re-program the VCR after turning the unit on again.

• OPTION BOX cover

This VCR provides an optional port for connecting an

optional module to the rear of the unit.

If you would like additional information regarding the

available options for this VCR please consult your dealer.

The installation of the optional module should be per­

formed only by qualified technical personnel.