background image

max 60 mm

min 32 mm

max 60 mm

min 18 mm

65 mm

722 mm

86 mm

769 mm

6

7

8

4. Screw both spindles (3) with

a nut (4) on each into one side of

the gate.

Screw both hinge-bars (5) into the

other side of the gate

5. Mark the position for the wall cup (6) and wall catch (7) on the opposite wall surface to

where you want the gate to hinge from. The top hole for the lower wall cup (6) should be 86mm

above the floor. The top hole for the upper wall catch (7) should be 769mm above the floor.

Likewise mark the position for the hinges (8) on the wall surface you want the gate to hinge from.

The top hole for the lower hinge

should be 65mm above the floor.

The top hole for the upper hinge

should be 722mm above the

floor. Fix the wall cup, catch and

hinges using appropriate fixings

depending on the wall surface:

wood screws for wood surfaces,

wall plugs and screws for brick /

concrete / plastered surfaces and

metal screws for metal surfaces.

These screws and fixings are not

provided.

A

4

3

5

6. Place the gate into position,

making sure to insert both of

the hinge bars (5) into the

hinges (8).

Adjust the spindles (3) so that

they fit comfortably into the

wall cup and wall catch.

7. Ensure that the distance

between the gate and the wall

on the latch side is no less than

18mm and no more than 60mm,

and that the distance between the

gate and the wall on the hinge

side is no less than 32mm and no more than 60mm.

Adjust the spindles and/or hinge bars as necessary

to achieve these distances.

8. Use the spanner provided to

tighten the nuts

8

3

5