Chapter 2. Data Extraction/Filtering Process

Filtering Criteria Definition

The possible filtering criteria parameters for barcode filtering are Numbering, Company code, and
Product code.

String filtering has no applicable filtering criteria. All serial/socket bytes are treated as raw data and
compared in the filtering process.

Example:

A DeviceMaster UP is connected to an RFID reader.

The PLC interface is enabled and is operating in RFID filtering mode. The PLC filtering criteria is set to
Company code and Product/Location code.

The application port is enabled and it is also operating in RFID filtering mode. The application filtering
criteria is set to Company code, Product/Location code, and Serial Number.

Six RFID tags are then read at one time. All have the same Company and Product/Location codes, but
different Serial Numbers.

-

The PLC will receive one RFID tag because all have the same Company and Product/Location codes.

-

The application will receive all six RFID tags because the Serial Number is included in the filtering
criteria and all six tags have unique serial numbers.