Data-only null- modem cables, Control loopback cables, Rs-422 to dte cables – Comtrol Cable User Manual

Page 7: Shielded vs. unshielded

Advertising
background image

Getting Started

[Documentation number: 2000430 Rev B] 7

Data-Only Null-Modem Cables

Data-Only Null-
Modem Cables

If no hardware flow is required, use the pinouts in the following figure. If you are
using a 3-wire cable and you need control, use software flow control.

Control Loopback
Cables

Some equipment may not require hardware handshaking. However, they may
require that certain control signals are active before sending data.

RS-422 to DTE
Cables

Most RS-422 communication links do not use hardware handshaking or signal ground lines.
The following figure shows twisted-pair transmission lines.

Shielded vs. Unshielded

If the Comtrol device falls within the limits for a Class A computing device
established by the FCC, the serial cables used to connect the Comtrol device to the
external devices must be shielded. The cable shield must connected to the chassis
ground at both ends to reduce EMI. If the cable shield is not connected to the
chassis ground at both ends, the EMI radiation from your system may exceed the
limits allowed for FCC class A equipment. You can use an isolation device if you
experience problems with ground loops.

Refer to the statement on electromagnetic compliance in the Comtrol hardware
document to determine the FCC class for your Comtrol product.

RocketPort Connector

Signal

TxD
RxD
GND

Name

DB25

2
3
7

Signal

RxD
TxD
GND

Name

Pins

DB9

2
3
5

Pins

DB25

3
2
7

Pins

Customer DTE Connector

RJ45

4
5
3

Pins

RJ11 DB9

3 3

4 2

2 5

Pins Pins

RocketPort Connector

Signal

TxD
RxD
RTS
CTS
DSR

GND

DCD
DTR

Name

DB25

2
3
4
5
6

7

8
20

Signal

RxD
TxD
RTS
CTS
DSR

GND

DCD

DTR

Name

Pins

DB9

2
3
7
8
6

5

1
4

Pins

DB25

3
2
4
5
6

7

8
20

Pins

Customer DTE Connector

RJ45

4
5
1
8
7

3

6
2

Pins

RJ11 DB9

3 3
4 2
N/A 7
N/A 8
N/A 6

2 5

5 1
1 4

Pins Pins

RocketPort Connector

TxD+

RxD+

Name

DB25

19

15

Signal

RxD+

TxD+

Name

Pins

Customer DTE

TxD-

25

RxD-

17

Signal

RxD-

TxD-

GND 7 GND

Connector

Advertising