Building an rs-485 test cable, Hardware specifications, Specifications – Comtrol RPSH-ia User Manual

Page 9

Advertising
background image

RocketPort® Serial Hub ia (RPSH-ia) Hardware Installation

9

Building an RS-485 Test Cable

Building an RS-485 Test Cable

You can use a straight-through cable

as illustrated previously

, or build your own

cable.

Hardware Specifications

This table illustrates environmental conditions.

The following table lists electromagnetic compliance certifications.

DB9

3

7

Pins

TxD or TRX-

RTS or TRX+

Signal

DB9

3

7

Pins

TxD or TRX-

RTS or TRX+

Signal

RS-485 Loopback Cable for WCOM or MiniCom

Note: The RS-485 loopback cable only requires

Pins 3 and 7 to be connected.

Environmental Conditions

Value

Air temperature:

System on (operational)
System off (storage)

0 to 60

o

C

-20 to 85

o

C

Altitude

0 to 10,000 feet

Heat output

9.6

BTU/Hr

Humidity (non-condensing):

System on (operational)
System off (storage)

8% to 80%

20% to 80%

Mean Time between Failures
(MTBF)

39.1 years

IEC Test

Status

IEC 68-2-1 Temperature Soak
Test

Yes

IEC 68-2-6 Sinusoidal
Vibration Test

Yes

IEC 68-2-34 Random
Vibration Test

Yes

Electromagnetic Compliances

Status

Emission:

Canadian EMC requirements

CISPR-22/EN55022

Class A

FCC Part 15 Class A

Yes

Immunity:

EN50082

(801-2

ESD

, 801-3 RF,

and 801-4

FT)

Yes

Safety:

EN60950
UL Listed

Yes