Comtrol 16-Port User Manual

Page 6

Advertising
background image

Hardware Installation

6

Specifications

Electromagnetic Compliance

Status

Emission:

Canadian EMC requirements ICES-003
CISPR-22/EN55022 Class A
FCC Part 15: Class A

Yes

Immunity:

EMC Directive 89/336/EEC

EN55024:

IEC 1000-4-2 Electro Static Discharge
IEC 1000-4-3 Radiant Electromagnetic Fields
IEC 1000-4-4 Fast Transient Burst
IEC 1000-4-5 Surge Transients
IEC 1000-4-6 Conducted Disturbance
IEC 1000-4-8 Power Frequency Magnetic Field
IEC 1000-4-11 Voltage Dips, Interruptions and Variations

Yes

EN60950; UL & CUL recognized.

Yes

RocketPort CompactPCI

Specification

Baud rate

50 to 230.4K baud

Bus interface

CompactPCI

Control by device driver:

Data bits
Parity
Stop bits

7 or 8

Odd, Even, None

1 or 2

Current consumption

+5V

+12V

-12V

+3.3V

330 mA

220 mA

320 mA 340 mA

Dimensions

100 mm x 160 mm

Heat output

32 BTU/HR

Serial ports/expansion slot

16

Interfaces (depending upon
model)

RS-232 and/or RS-422

Mean time between failures
(MTBF)

40.6 years

RocketPort boards/system

4

Surge protection:

Standard and rack mount
interface boxes

Surge interface box

Provides ESD surge protection for a minimum
of 10KV @ 200A for a duration of 1ns.

Provides ESD surge protection for a minimum
of 25KV @ 200A for a duration of 1ns.

Weight (board, only)

5.5 oz.