Operation

6

Operation

The C52/C53 supports four kinds of operations. They are:

Point-to-point, 4-wire full duplex

Point-to-point, 2-wire half duplex

Multidrop, 4-wire full duplex

Multidrop, 2-wire half duplex

Note: If possible, connect the GND of both sides together to gain better signals. For example, you may need one more GND connection in

addition to the 4-wire or 2-wire connections.

Note: For C53, connect the GND at the terminal block to the earth ground to provide a ground path to prevent electric shock caused by

lightning, no matter whether you use the RJ45 or terminal block RS-422/RS-485.

Basic Communication Wiring

Before placing a converter in an existing network, you should configure it. The following diagrams show a typical layout for both
converters.

Power

Power GND

RS-422/485

RS-422/485

RS-232

PC

Power

TxD(2)

RxD(3)

RTS(4)

CTS(5)

DSR(6)

GND(7)

DCD(8)

DTR(20)

RxD(2) TxD+(B))

TxD(3) TxD-(A)

CTS(4) RxD+(B)

RTS(5) RxD-(A)

DTR(6) GND

GND(7)

DCD(8)

DSR(20)

RxD+(B)

TxD+(B)

TxD-(A)

GND

RxD-(A)

RS-232

Host

D 25 Female

Connector

B

A52/53 Converter

RS-422 Devices

TxD(2)

RxD(3)

RTS(4)

CTS(5)

DSR(6)

GND(7)

DCD(8)

DTR(20)

RxD(2) Data+(B))

TxD(3) Data-(A)

CTS(4) GND

RTS(5)

DTR(6)

GND(7)

DCD(8)

DSR(20)

Data+(B)

Data

GND

-(A)

RS-232

RS-485

Host

D 25 Female

Connector

B

A52/53 Converter

RS-485 Devices

Advertising
This manual is related to the following products:

C52