Db25 interfaces, Building db25 female loopback plugs – Comtrol RocketPort PCI series User Manual

Page 8

Advertising
background image

8

DB25 Interfaces

DB25 Interfaces

This section describes the DB25
interface connectors. Standard
interface modules use female DB25
connectors, while the Surge interface
module, Quadcable, and Octacable
fanouts use male connectors.

This table shows connector information for DB25 connectors.

Building DB25
Female Loopback
Plugs

Loopback connectors are plugs, with pins wired
together as shown, that are used in conjunction with
the RocketPort diagnostic software to test serial ports.

This loopback is used with the Quadcable and
Octacable. To build a DB25 loopback plug for an
Quadcable or Octacable, wire the following pins
together:

Pins 2 to 3

Pins 4 to 5 to 22

Pins 6 to 8 to 20

To build a DB25 loopback plug (surge interface
model) for an RS-422 serial connection, wire the
following pins together:

Pins 15 to 19

Pins 17 to 25

Interface Modules

Quad/Octacable

Pin

RS-232

Signal

RS-422

Signal

RS-232

Signal

1

Not used

Not used

Not used

2

TxD

Not used*

TxD

3

RxD

Not used*

RxD

4

RTS

Not used*

RTS

5

CTS

Not used*

CTS

6

DSR

Not used*

DSR

7

Signal ground

Signal ground*

Signal ground

8

DCD

Not used*

DCD

9 to 14

Not used

Not used

Not used

15

Not used

RxD+

Not used

16

Not used

Not used

Not used

17

Not used

RxD-

Not used

18

Not used

Not used

Not used

19

Not used

TxD+

Not used

20

DTR

Not used*

DTR

21 to 24

Not used

Not used

Not used

25

Not used

TxD-

Not used

*

All RS-232 signals are present in RS-422 mode. The quad/
octacables do not support RS-422 mode.

Pin 13

Pin 1

Pin 25

Pin 14

DB25 Female

Pin 14

Pin 25

Pin 1

Pin 13

DB25 Male

Pin 13

Pin 1

RS-232 Only (Back View)

Pin 14

Pin 25

Pin 25

Pin 14

Pin 13

Pin 1

RS-422 Only (Back View)