Operating conditions, Hardware specifications, Electromagnetic compliance – Comtrol RM II V.90 User Manual

Page 6: Technical support

Advertising
background image

Operating Conditions

This table illustrates environmental conditions:

Hardware Specifications

The following table illustrates hardware specifications:

Electromagnetic Compliance

This table lists electromagnetic compliance
certifications:

Technical Support

If you need technical support, contact Comtrol using one
of the following methods.

Corporate Headquarters:

email:

[email protected]

FAX: (651) 631-8117

Phone: (651) 631-7654

FTP

Site:

ftp://ftp.comtrol.com

Web Site:

http://www.comtrol.com

Comtrol Europe:

email:

[email protected]

FAX

: +44 (0) 1 869-323-211

Phone: +44 (0) 1 869-323-220

Web Site:

http://www.comtrol.co.uk

Comtrol has a staff of technical support specialists
available to help you.

First Edition, December 21, 1998
Copyright © 1998. Comtrol Corporation.
All Rights Reserved.

Comtrol Corporation makes no representations or
warranties with regard to the contents of this reference
product or to the suitability of the Comtrol product for
any particular purpose. Specifications subject to change
without notice. Some software or features may not be
available at the time of publication. Contact your
reseller for current product information.

Trademark Notices

Comtrol and RocketModem are trademarks of Comtrol
Corporation.

RocketPort is a registered trademark of Comtrol
Corporation.

Micro Channel is a registered trademark of
International Business Machines Corporation.

Other product names mentioned herein may be
trademarks and/or registered trademarks of their
respective owners.

2000003 Revision A

Environmental Conditions

Value

Air temperature:

System on
System off

0 to 40

o

C

-20 to 85

o

C

Altitude:

0 to 10,000 feet

Humidity (non-condensing):

System on
System off

8% to 80%

20% to 80%

Description

Specification

Baud rate

300 to 56 Kbps

Bus interface

PCI

Card dimensions (meets PCI

specifications)

12.4” by 4.2” (w x h)

Cards per system

4

Current consumption (+5V):

RocketModemII 4
RocketModemII 6

1.7A max
2.3A max

Device driver control:

Data bits
Parity
Stop bits

7 or 8

Odd, Even, None

1 or 2

Heat output:

RocketModemII 4
RocketModemII 6

29 BTU/hr

39.2 BTU/hr

Interrupt (driver dependent)

None, 3, 4, 5, 9, 10,

11, 12, and 15

Mean time between failures:

RocketModemII 4
RocketModemII 6

18.3 years
13.7 years

Modems per card

4 or 6

Modems per system

4 to 24

Power consumption:

RocketModemII 4
RocketModemII 6

8.5 W

11.5 W

Telco connector

RJ11

Weight (card only):

RocketModemII 4
RocketModemII 6

10 oz
11 oz

Electromagnetic Compliance

Status

Emission:

Canadian EMC requirements
FCC Class B Certification

Yes

Safety:

UL Listed

Yes

FCC Part 68 Certification

Yes

Advertising