Comtrol RocketPort 550 uPCI Linux User Manual

Page 6

Advertising
background image

6

Important Note

If running SuSE Linux then use

install.SuSE instead of install

[root@localhost inst_Comtrol]# ./install

===========================================================

Comtrol Europe RocketPort 550 Drivers installation

Version (x.yy)

(Month year)

===========================================================

Press Enter to begin installation

Where (x.yy) is the release ‘major.minor’ number, and ( month year ) is the release date.


Press enter to begin installation.


A screen of text is displayed. It contains information about the names you can

select for the RocketPort 550 ports and details how the driver assigns numbers to
individual ports.

Your system will connect to the RockPort 550 Ports through entries

in the /dev/ directory. You can choose any prefix for the names,

as long as it is different from names given to other devices.

For example, if you select a prefix of 'ttyA', then the RocketPort 550

Ports will be called /dev/ttyA00, /dev/ttyA01 and so on up to

/dev/ttyA63

You can install up to 4 RocketPort 550 cards in a system. The device names

for the first card starts with ttyA00, the second starts ttyA16, the third

ttyA32, and the fourth ttyA48. If the installed cards have less than

16 ports, then there will be gaps in the numbering corresponding to the

missing ports.

Advertising