I/O CONNECTORS

INPUT:
The maximum input level for the Flamingo is +18 dBm with the unit’s gain set at 6 db. The input is bal-
anced with pin 2 being signal positive and pin 3 signal negative. The input connector is a XLR connec-
tor.

OUTPUT:
The maximum output level for Flamingo is +25 dBm. The XLR connector is wired with pin 2 hot or signal
“+”, pin 3 signal negative and pin 1 signal ground. If it is necessary to run the output unbalanced, tie pin 3
to pin 1 at the XLR connector.

POWER
Flamingo can run on 4 different line voltages.

Please have voltage and fuse changed by a qualified

technician.

The two voltage selection switches are located inside the unit near the power connector. The

unit MUST BE UNPLUGGED when changing voltage.

VOLTAGE AND FUSE TYPE:
100, 120, 230, 240 volt; 50/60 Hz; 45 watts
MDL 0.5A Fuse for 100V and 120V
MDL 0.3A Fuse for 230V and 240V

Pilot Lamp: # 7335

Shipping Weight: 15 lbs. (8.6 kg)

Depth Behind Panel: 10 inches (31.75 cm) plus cabling

Panel Height: 1 rack space

Noise:

Input Impedance: 8.5K ohms

Frequency Response:

8