Operation / maintenance – Continental CVF36P User Manual

Page 11

Advertising
background image

11

W415-0298 / K / 12.06.07

When lighting and re-lighting, the gas knob cannot be turned
from pilot to off unless the knob is depressed.

1. STOP! Read the above safety information on this la-

bel.

2. Set the thermostat to lowest setting.
3. Turn off all electric power to the fi replace.
4. Open the control door. Turn the gas knob clockwise

to off.

5. Wait fi ve (5) minutes to clear out any gas. If you smell

gas including near the fl oor, STOP! Follow “B” in the
above safety information on this label. If you don’t smell
gas go to the next step.

6. Find pilot located in front of the back log.
7. Turn gas knob counter-clockwise to

pilot.

B. Before operating smell all around the fi replace area for

gas and next to the fl oor because some gas is heavier
than air and will settle on the fl oor.

C. Use only your hand to push in and turn the gas control

knob. Never use tools. If the knob will not push in and
turn by hand, do not try to repair it. Call a qualifi ed service
technician. Force or attempted repair may result in a fi re
or explosion.

D. Do not use this fi replace if any part has been under water.

Immediately call a qualifi ed service technician to inspect the
fi replace and replace any part of the control system and any
gas control which has been under water.

• Do not try to light any appliance.

• Do not touch any electric switch; do not use any phone

in your building.

• Immediately call your gas supplier from a neighbour’s

phone. Follow the gas supplier’s instructions.

• If you cannot reach your gas supplier, call the fi re depart-

ment.

WARNING:

IF YOU DO NOT FOLLOW THESE INSTRUCTIONS EXACTLY, A FIRE OR EXPLOSION

MAY RESULT CAUSING PROPERTY DAMAGE, PERSONAL INJURY OR LOSS OF LIFE.

A. This fi replace is equipped with a pilot which must be
lit by hand while following these instructions exactly.

GAS KNOB

OXYGEN DEPLETION SENSOR

If heater shuts off, do not relight until you provide fresh
air. If heater keeps shutting off, have it serviced. Keep
burner and control compartment clean.

When lit for the first time, the fireplace will emit a slight
odour for a few hours. This is a normal temporary condi-
tion caused by the curing of the logs and the “burn-in” of

internal paints and lubricants used in the manufacturing
process and will not occur again.

After extended periods of non-operation such as follow-
ing a vacation or a warm weather season, the fireplace
may emit a slight odour for a few hours. This is caused by
dust particles burning off. In both cases, open a window
to sufficiently ventilate the room.

8. Depress and hold gas knob while lighting the pilot with

the push button igniter. Keep knob fully depressed for
one minute, then release. If pilot does not continue to
burn repeat steps 3 through 7.

9. With pilot lit, turn gas knob counter-clockwise t o

on. When the pilot has been turned off, ignition of the
main burner may be delayed from 1-2 minutes.

When the pilot has been left burning, ignition of the main

burner should occur almost immediatley.

10. If equipped with remote on-off switch, main burner may

not come on when you turn the valve to on. Remote switch
must be in the on position to ignite burner.

11. Turn on all electric power to the fi replace.

1. Turn off all electric power to the fi replace if service is to

be performed.

2. Push in gas control knob slightly and turn clockwise

to off. Do not force.

GAS KNOB AT OFF

OPERATION / MAINTENANCE

FOR YOUR SAFETY READ BEFORE LIGHTING:

WHAT TO DO IF YOU SMELL GAS:

LIGHTING INSTRUCTIONS

TO TURN OFF GAS

FIGURE 25

FIGURE 26

FIGURE 27

Advertising
This manual is related to the following products: